4.1 UP-3301 IPL
No
Procedure on P.C. side
1
Install "UTL33.EXE" on the P.C.
6
Connect P.C. and UP-3301 via RS232.
7
Execute "UTL33.EXE" on P.C.
Operation:
>UTL33 3301_1.ROM 3301_2.ROM
("3301_1.ROM" and "3301_2.ROM" are file name of S-type
ROM object.)
8
Program data is sent to UP-3301 automatically.
9
"UTL33.EXE" is completed.
P.C. shows
"Completed."
No
2
Turn OFF the power.
3
Select "IPL Mode".
Set the "IPL Switch" of UP-3301 to "ON".
4
Turn ON the power.
5
Starting of "IPL Mode".
The UP-3301 displays
"IPL from Serial I/O"
8
Program data is received from P.C. automatically.
The UP-3301 displays
9
The UP-3301 displays
"Completed."
10
Turn OFF the power.
11
Select "Normal Mode".
Set the "IPL switch" to "OFF".
12
Execute the "Service Reset" on UP-3301.
UP-3301US SERVICE PRECAUTION
– 15 –
Procedure on UP-3301 side
IPL from IR
Connected IRDA 115200
21 22 23 24 25 26 27 28
IPL from Serial I/O
Connected IRDA 115200
21 22 23 24 25 26 27 28
29 2A 2B 2C 2D 2E 2F
Completed.
IPL from Serial I/O
Connected IRDA 115200
30 31 32 33 34 35 36 37
38 39 3A 3B 3C 3D 3E 3F
Completed.