7-2. Optional Generator Power Receptacles

Notes
.
A complete Parts List is available at www.MillerWelds.com
!
.
1
Combined output of all receptacles limited to
the rating of the generator. Maximum output
is 10.5 kVA/kW for Kohler-powered models,
11 kVA/kW for Subaru-powered models.
CSA/GFCI Receptacle Option
1
GFCI2 and GFCI3 supply 60 Hz single-
phase power at weld/power speed. Maxi-
mum output from GFCI-2 or GFCI-3 is 2.4
kVA/kW. Circuit protection is the same as
standard receptacles.
If a ground fault is detected, the GFCI Reset
button pops out and the circuit opens to dis-
connect the faulty equipment. Check for
damaged tools, cords, plugs, etc. con-
nected to the receptacle. Press button to re-
set receptacle and resume operation.
!
.
If unit does not have GFCI recep-
tacles, use GFCI-protected exten-
sion cord.
Generator power decreases as weld
current increases.
Set Fine Control R1 at 10 for full genera-
tor power.
120 V 20 A AC GFCI Receptacles
GFCI-2 and GFCI-3
Power is still present at the 240 volt
receptacle when only one circuit
breaker trips.
Unplug power cord before attempt-
ing to service accessories or tools.
At least once a month, run engine at
weld/power speed and press Test but-
ton to verify GFCI is working properly.
Ref. 240 947-A
Work like a Pro!
Pros weld and cut
safely. Read the
safety rules at
the beginning
of this manual.
OM-4434 Page 37