"0" positioning of the dial gauge
Surface plate
① Put the tool (J18001-1) on the surface plate, and set the dial gauge to "0".
② Turn the index ring in the direction of the arrow, and shift the position by "0.17 mm" from 0 that was set in
① . (This is "0"-position of D200.)
③ Measure the body back based on "0" reference position of the index ring.
Measure 4 parts from the bayonet face to the CCD-PCB
attaching face.
 
Standard:48.5±0.015mm/ Parallelism: within 0.015mm
In case it is out of standard, make an adjustment
by loosening screws that attach the front and rear
bodies,
by putting the washer(s) on the contact
or
surface between the front body and rear body.
0" position of D200
Measure the outside angle of view.