Inspection And Adjustment Of Body Back - Nikon D3 VBA18001 Repair Manual

Table of Contents

Advertisement

Inspection and Adjustment of Body back

【"0" positioning of Dial gauge】
① Put the tool (J18001-1) on the surface plate.
② Turn the index circle in the direction of the arrow by three scale markings.
This is "0" position of D3.
Surface plate
【How to measure】
・ Measure six places from the bayonet face to the image PCB attaching face.
 
  S�a�dard: 48.64±0.015mm / Para��e�ism: 0.015mm �r �ess
・ In case it is out of standard, make an adjustment by putting the washer on the contact surface between the
front body and rear body.
Note: For some bodies, the washer(s) is/are already put on the attaching face of the image sensor unit.
There is a red mark indication at the following two positions.
  1. Indication: on the attaching face of the camera body side
    Purpose:To adjust the height of the camera body
  2. Indication: on the attaching face of the image sensor unit side
    Purpose:To adjust the height of the image sensor unit
Therefore, in case of the above 1. and when the camera body is disassembled or the image sensor is
replaced, put the washer(s) at the original position. In case of the above 2. and when the image sensor unit
is replaced, remove the washer.(s)
Index circle
" " Places to be
measured
- A  ・
-
logo Q0440 forGraphic
070518 Gdesign ito
INC
VBA18001-R.3719.A
"0" position of D3
Measurement terminal