With thermostatic valve electric heating or hot water heaters, the Comfort temperature can
be provided by adjusting the thermostat of each radiator. In this case, only the Economy
and Frost Protection temperatures are set by the TYBOX.

Air conditioning function

If you have a reversible heating / cooling system, change the setting on the CF04 menu to
equal 1. You are now authorised to switch the Tybox between heating and cooling modes.
(see the section on "Changing the heating / cooling mode")
CF04
0
Air-conditioning function not authorised. (by default)
1
Air-conditioning function authorised.
Enter your desired setting using the + or - buttons
Press OK to confirm and move on to menu CF05
Switching the value on menu CF04 to 0 is only possible when the TYBOX is in heating
mode
- 14 -

Circulator anti-seizing

If your thermostat controls a circulator, set the value of the CF05 menu to equal 1.
CF05
0
Anti-seizing off (by default)
Anti-seizing enabled (circulator operates for 1 minute
1
every 24 hours)
Enter your desired setting using the + or - buttons
Press OK to confirm and move on to menu CF06

Control time base

Select the time base recommended for your type of installation
15 min (recommended for controlling convectors or traditional
CF06
0
radiators). (by default)
30 min (recommended for controlling heat pumps, depending
1
on the model)
45 min (recommended for controlling heat pumps, depending
2
on the model)
Enter your desired setting using the + or - buttons
Press OK to confirm
- 15 -