I-Series Indoor Gas Fireplace

Section 2: Installation

Install Dimensions:

The install size requirements of your fireplace insert are dependent on several factors. Gas line location, electrical connection and gas
line type can play into what the minimum installation size can be. The diagram below illustrates the smallest possible size requirement
of this model. Please take into consideration these other factors when determining if this appliance will fit into your masonry or
manufactured fireplace.
15"
381mm
Figure 1 Sec.2
34DFID-S installation dimensions

Clearances:

The 34DFID-S Insert is designed and built to be installed into masonry or manufactured fireplaces. There is no requirement to have
a non-combustible hearth in front of the unit. Clearances to the underside of the mantel or sidewall are measured from the edge of
the door/screen front. The Mantel is shown as 10" maximum at a distance of 23" minimum from the door edge top. The mantel can
be extended further providing that you increase the height proportionately. For instance, if you want a mantel that is 2" beyond the
10" minimum, you have to install it 2" above the 23" minimum.
Faceplate
Figure 2 Sec.2
34DFID-S clearances
Page 8
Installation
24"
610mm
34"
864mm
Mantel
23"
584
Min
6"
152mm
24"
610mm
Gas and Electrical
Supply at Right Side
10"
254
Max
Side Wall
1
8
"
2
216
Min
Hearth Protection
**Hearth protection is not required if the unit
is installed with a 2" (50.8mm) elevation or
greater above the hearth surface** See the
section on 4 sided surround options.
10"14"18"24"26" 30"34"38 42
45"
XG0508-