Lp Conversion - Montigo 34FIDN-S-F [NG] Installation And Maintenance Manual

I-series indoor residential fireplace insert
Hide thumbs Also See for 34FIDN-S-F [NG]:
Table of Contents

Advertisement

I-Series Indoor Gas Fireplace
Figure 5 Sec.5 Location of Door retainer tabs
Check that the door retainers are properly engaged. If they are
not the door relief system may not operate properly. This can
cause a risk of injury or improper operation of the appliance.
WARNING
When installing the replace - gas lines, ttings,
accessories or any other objects cannot impede the
proper movement of the door buckles.
Page 16
Installation

LP Conversion

The 34FID-S is available in Natural Gas or Liquid Propane versions.
Should you have a Natural Gas unit that you would like to burn
Propane with; you can purchase an optional LP conversion kit
and install it using the following steps. To convert the unit to LP,
the unit must be disconnected from any gas supply, disconnected
from any electrical supply and batteries and removed from any
installation cavity.
The 6 major items that need modification to convert a unit to LP
1). Variable regulator on the gas valve
2). The main burner orifice
3). The pilot burner orifice
4). Set minimum primary air tab
5). Label on the valve showing the new specifications
6). Gas fitter conversion label
Figure 1 Sec.6 LP conversion kit showing pilot orifice, main burner
orifice, LP stepper motor, zap strap and gas fitter conversion label.
XG0508-
150204

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

34fidl-s-f [lp]

Table of Contents