Programming 2-OPX Modules

The 2-OPX Module is a two-channel device that represents two station ports. The first channel is called the
primary station; the second channel is called the secondary station. The primary station auto-IDs when you
plug in the 2-OPX Module. It has the same station and extension number as a keyset would plugged into the
same port. You must set up the secondary station in programming.
To set up the 2-OPX Module secondary station:
In 9902 - Set Up Stations (DS1000), assign an unused station number (e.g., 27) to the 2-OPX Module
secondary station. (If you use station 27, the secondary station's extension number will be 326.) Refer
to 9902 - Set Up Stations (DS1000) in the Software Manual on the System Document CD that came
with your system for more.
Note: You must set up the 2-OPX Module secondary station before it will function.

Wall Mounting the 2-OPX Module

To wall mount a 2-OPX Module (Figure 4-8):
1.
Following the diagram below, switch the screws that secure the 2-OPX Module cover from the outside
holes to the inside holes. Do not tighten the screws.
2.
Attach the wall mount brackets to each side of the 2-OPX Module and tighten the screws.
3.
With the connectors facing down, mount the 2-OPX Module to the wall using suitable customer-pro-
vided fasteners.
4.
Connect the 2-OPX module as described on the previous page.
DS1000 Hardware Manual
Use the 2-OPX Module as its own mounting template.
Figure 4-8: Wall Mounting the 2-OPX Module
2-OPX Module
Section 4: Optional Equipment ◆ 4-11