NEC DS1000 Operation Manual page 50

Hide thumbs Also See for DS1000:
Table of Contents

Advertisement

Database Transfer Utility
9.
When the Database Transfer completes, set the MODE switch on the source system back to RUN and
press the red reset button.
10. To repeat the Database Transfer procedure, you must start over again from step 1.
While Database Transfer is in
progress:
When Database Transfer
completes:
5-8 ◆ Section 5: Maintenance Options and SMDR
If the destination system does not recover from the reset, the transfer was incomplete and the data-
base has become corrupted. You'll need to shut the system down, pull the battery from the CPU (for
about 5 minutes) and then restart the system. The default database will automatically be reinstalled.
Table below explains the Power LED flash rates that occur during Database Transfer.
Power LED Flash Rates During Database Transfer
Source System
Flashes briefly red, then flashes
green.
Flashes red/green.
Destination System
Flashes briefly green, the alter-
nately flashes red and green.
Flashes slowly green.
DS1000 Hardware Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds2000