6-5. Description of DIP switches

6-5-1. Panel DIP switches

Always turn off the power supply before changing any of the DIP switch settings.
Any changes to the DIP switch positions will not be effective until the power is switched off and back on again.
DIP switch A
No.
ON/OFF
ON
1
OFF
ON
2
OFF
ON
3
OFF
ON
4
OFF
ON
5
OFF
ON
6
OFF
ON
7
OFF
ON
8
OFF
Work clamp remains lowered after sewing is complete (rises when treadle is
depressed backward)
Work clamp rises after sewing is complete
-
-
Pausing enabled during automatic sewing when the treadle is depressed
backward
Pausing disabled during automatic sewing when the treadle is depressed
backward
Display setting during automatic mode = bobbin thread counter (Default: 100)
Display setting during automatic mode = production counter (Default: 0)
2-cycle sewing ON (All programs will be set to 2-cycle sewing regardless of
the setting for parameter No. 55.)
2-cycle sewing OFF
-
-
Upper thread breakage detection disabled
Upper thread breakage detection enabled
Programs disabled
Programs enabled
6. ELECTRIC COMPONENTS AND SOFTWARE
Note:
Setting items
HE-800A
Move the switches properly.
3993Q
Default
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
139