6. ELECTRIC COMPONENTS AND SOFTWARE
3. Circuit board connectors [1-step power supply circuit board]
CN1
Pin no.
1
P8V (+8V)
2
0V
3
N8V (-8V)
4
OV. Det
5
RY. out
6
OV. FAULT
7
+5V
8
PHOTO
9
U
10
V
11
W
12
U
13
V
14
W
15
IPM. FAULT
CN2
Pin no.
1
AC200-R (200V specifications)
2
AC200-T (200V specifications)
3
-
4
-
CN3
Pin no.
AC220-R
1
(100/110/220/380/400V specifications)
2
-
AC220-T
3
(100/110/220/380/400V specifications)
4
-
CN4
Pin no.
1
AC230/240-R (230V specifications)
2
-
3
-
4
AC230/240-T (230V specifications)
CN5
Pin no.
1
DC300V
2
DC0V
CN6
Pin no.
1
Resistance
2
Resistance
136
Signal name
Signal name
Signal name
Signal name
Signal name
Signal name
Probable symptoms due to poor contact
• The zigzag home position can not be found.
• The zigzag mechanism does not operate.
• Error E-05 is displayed.
• The machine motor does not turn.
Probable symptoms due to poor contact
• The zigzag home position can not be found.
• The zigzag mechanism does not operate.
• Error E-05 is displayed.
• The tension release solenoid does not operate.
Probable symptoms due to poor contact
• The zigzag home position can not be found.
• The zigzag mechanism does not operate.
• Error E-05 is displayed.
• The tension release solenoid does not operate.
Probable symptoms due to poor contact
• The zigzag home position can not be found.
• The zigzag mechanism does not operate.
• Error E-05 is displayed.
• The tension release solenoid does not operate.
Probable symptoms due to poor contact
• The zigzag home position can not be found.
• The zigzag mechanism does not operate.
• Error E-05 is displayed.
Probable symptoms due to poor contact
• Voltage error occurs.
• Error E-95 is displayed.