Programming Rs-485; Initialize Com Port - FabiaTech FX5634 Fanless Series User Manual

Table of Contents

Advertisement

FabiaTech Corporation

Programming RS-485

The majority communicative operation of the RS-485 is in the same of the RS-232.
When the RS-485 precedes the transmission, which needs control the TXC signal,
and the installing, steps are as follows:
Step 1:
Enable RTS
Step 2:
Send out data
Step 3:
Waiting for data empty
Step 4:
Disable RTS
Note: Please refer to the section of the "Serial Ports" in the Chapter 5 "Technical
Reference" for the detail description of the COM ports register.

Initialize COM port

Step 1:
Initialize COM port in the receiver interrupt mode, and /or transmitter
interrupt mode. (All of the communication protocol buses of the RS-485
are in the same.)
Step 2:
Disable TXC (transmitter control), the bit 1 of the address of offset+4
just sets "0".
NOTE: Control the FX5634 system "RTS" signal to the RS-485 TXC communication.