WallVIEW CCU HD-20 HD-SDI Inside Front Cover - Blank WallVIEW CCU HD-20 HD-SDI Manual 342-0182 Rev. A Page 2 of 24...
Page 3
Read and understand all instructions before using. Do not operate any device if it has been dropped or damaged. In this case, a Vaddio technician must examine the product before operating. To reduce the risk of electric shock, do not immerse in water or other liquids and avoid extremely humid conditions.
Page 4
IR sensors are built into the front of the ClearVIEW HD-20 to receive IR signals from the IR remote control supplied with the camera. 4) Blue Power Light: A Vaddio blue power light is illuminated when the camera is turned on. Compatible Vaddio Switchers and Joystick Controllers: Precision Camera Controller ProductionVIEW™...
WallVIEW CCU HD-20 HD-SDI ClearVIEW HD-20 PTZ Camera, Rear View with Feature Call-outs: ⑤ ⑨ ⑥ ⑩ ⑦ ⑪ ⑧ ⑫ 5) RS-232 IN & IR Out: The RS-232 accepts modified VISCA protocol for camera control, as well as transmits IR signaling received by the IR receivers, which can be transmitted to third party devices.
Page 6
WallVIEW CCU HD-20 HD-SDI Quick-Connect CCU Front Panel Controls (left to right): Tally Light: The blue LED tally light on the front panel is tied to the tally contacts on the rear panel allowing the user to easily track which camera interface is being used in a multi-camera system by supplying a simple contact closure. LCD Display: Backlit (blue) display indicates which parameter (iris, detail, etc.) is being adjusted.
Page 7
Tally on 2-pin Phoenix-type Connector: Contact closure lights a Vaddio blue LED on front panel allowing indication of which CCU/camera combination is active in a multi-camera/CCU installation. A tally command will also be sent to the HD-20 camera to illuminate the red LED on the camera’s base.
Page 8
Using only the most advanced and leading edge components available today, the EZIM HD-SDI Slot Card paired with the HD-20 PTZ camera produces remarkable picture quality. Anatomy of the Vaddio EZIM HD-SDI Slot Card: 1) Two (2) HD-SDI/SDI Outputs on BNC a.
Page 9
WallVIEW CCU HD-20 HD-SDI Installing the EZIM HD-SDI Slot Card: • The Slot Card will be packed separately. install the EZIM HD-SDI Slot Card, remove all and be certain that the HD- power connections 20 camera is not powered up before attempting to install the EZIM HD-SDI Slot Card.
Page 10
The IR output is sent out on the RS-232 RJ-45 jack on the back of the camera. Turning on the IR output will allow IR signals to be transmitted over the Cat-5e cable to the head end. When using RS-232 control or Vaddio CCU controllers (also via RS-232), turn the IR OUT to OFF.
Page 11
For RS-232, use a standard straight through Cat-5e cables (568B termination) from the RS-232 port on the back of a Vaddio camera controller or switcher to the camera. If the camera is connected to a third-party control system (such as AMX or Crestron), a DB-9 to RJ-45 control adapter cable is supplied.
Page 12
RS-232 IN Jack RS-232 HD-SDI HD-SDI Program HD-SDI Preview Monitors (No zoo inhabitants or zoo janitors were harmed in the making of the simulated video) Vaddio ProductionVIEW HD-SDI Console WallVIEW CCU HD-20 HD-SDI Manual 342-0182 Rev. A Page 12 of 24...
Page 13
Step 4: Connect the Vaddio 36 VDC, 2.78A power supply to the Quick-Connect CCU and then the AC side into an AC outlet. Power will travel down the Power Cat-5e cable to the camera. The camera will “Home” to a centered position ready for control information from CCU and the camera controller (ProductionVIEW HD or maybe the Precision Camera Controller).
Page 14
General Specifications: WallVIEW CCU HD-20 HD-SDI WallVIEW CCU HD-20: 999-6957-000 (North America) Part Numbers WallVIEW CCU HD-20: 999-6957-001 (International) Vaddio ClearVIEW HD-20 6.49mm diagonal (1/2.8 Type) Exmor High-speed CMOS Image Sensor Image Device 3.27M pixels (Effective) Picture Elements 1080/60i, 1080/50i, 720/60p, 720/50p, 1080/30p and 1080/25p (SD Resolutions Not Supported) HD Resolutions 20x Optical Zoom, 11-Element HiLD™...
Page 15
Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference including interference that may cause undesired operation of the device. Changes or modifications not expressly approved by Vaddio can affect emission compliance and could void the user’s authority to operate this equipment.
Page 16
Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference including interference that may cause undesired operation of the device. Changes or modifications not expressly approved by Vaddio can affect emission compliance and could void the user’s authority to operate this equipment.
Page 17
Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference including interference that may cause undesired operation of the device. Changes or modifications not expressly approved by Vaddio can affect emission compliance and could void the user’s authority to operate this equipment.
Vaddio Customer Service: Vaddio will test, repair, or replace the product or products without charge if the unit is under warranty and is found to be defective. If the product is out of warranty, Vaddio will test then repair the product or products. The cost of parts and labor charge will be estimated by a technician and confirmed by the customer prior to repair.
WallVIEW CCU HD-20 HD-SDI Appendix 1: YPbPr Video Pin-Out for the HD-20 Camera & Quick-Connect Analog YPbPr Output YPbPr Pr GND Y GND Pb GND EZIM HD-SDI Slot card Pin out Assignments (568B Wiring Standard) Power Connector RJ-45 Power Power+ Power- Power+ 12345678...
TXD (to RXD of control source) No Flow control NOTE: The Vaddio ClearVIEW HD-20 Control Protocol is similar, but not identical to the Sony® VISCA™ command set in order to be compatible with several popular control devices. Not all VISCA commands are supported and there are many HD-20 specific commands in the following Command and Inquiry Lists.