Vaddio wallview hd-20 dvi/hdmi high definition robotic ptz camera featuring the quick-connect™ dvi/hdmi sr interface and the conceal™ wall mounting system (20 pages)
Vaddio wallview ccu hd-20 high definition ptz camera featuring the quick-connect ccu interface with the ezim ccu slot card and the conceal wall mounting system (20 pages)
Read and understand all instructions before using. Do not operate any device if it has been dropped or damaged. In this case, a Vaddio technician must examine the product before operating. To reduce the risk of electric shock, do not immerse in water or other liquids and avoid extremely humid conditions.
Page 4
3 party remotes for the IR forwarding feature. 4) Blue Power Light: A Vaddio blue power light is illuminated when the camera is turned on. Compatible Vaddio Switchers and Joystick Controllers: AutoPresenter...
Page 5
ClearVIEW HD-19 ClearVIEW HD-19 PTZ Camera, Rear View with Feature Call-outs: ⑤ ⑨ ⑥ ⑩ ⑦ ⑪ ⑧ ⑫ 5) RS-232 IN & IR Out: The RS-232 accepts modified VISCA protocol for camera control, as well as transmits IR signaling received by the IR receivers, which can be transmitted to third party devices.
Page 6
For RS-232, use a standard Cat-5e cable and RJ-45 connectors (568B termination) from the RS-232 port on the back of a Vaddio camera controller or switcher. If the camera is connected to a third-party control system (such as AMX or Crestron), a DB-9 to RJ-45 control adapter cable is supplied.
Page 7
IR Out 3: The IR output is sent out on the RS-232 RJ-45 jack on the back of the camera. Turning on the IR output will allow IR signals to be transmitted over the CAT-5 cable to the head end. When using RS- 232 control or Vaddio CCU controllers (also via RS-232), turn the IR OUT to OFF. ...
Page 8
ClearVIEW HD-19 System Connectivity Example 1: Basic system connectivity of a Vaddio WallVIEW™ DVI/HDMI HD-19 and Quick-Connect DVI/HDMI SR Interface with Vaddio ProductionVIEW™ Precision Camera Controller and PreVIEW HD Monitors. WallVIEW DVI/HDMI HD-19 System Power to Camera HSDS Video from...
ClearVIEW HD-19 System Connectivity Example 2: System connectivity of two (2) Vaddio HD-19 cameras and two (2) Quick- Connect DVI/HDMI SR Interfaces configured with single control port codec and Daisy Chain Control Emulation (DCCE). WallVIEW DVI/HDIM HD-19 HD Camera Systems...
Page 10
Step 7: Connect the Vaddio 24 VDC, 2.0A power supply to the POWER Connector on the Quick-Connect and plug the power adapter into an AC outlet. Power will travel down the Power/Video Cat-5e cable to the camera.
Page 12
Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference including interference that may cause undesired operation of the device. Changes or modifications not expressly approved by Vaddio can affect emission compliance and could void the user’s authority to operate this equipment.
Page 13
Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference including interference that may cause undesired operation of the device. Changes or modifications not expressly approved by Vaddio can affect emission compliance and could void the user’s authority to operate this equipment.
Vaddio Customer Service: Vaddio will test, repair, or replace the product or products without charge if the unit is under warranty and is found to be defective. If the product is out of warranty, Vaddio will test then repair the product or products. The cost of parts and labor charge will be estimated by a technician and confirmed by the customer prior to repair.
ClearVIEW HD-19 Appendix 1: YPbPr Video Pin-Out for the HD-19 Camera and Quick-Connect SR Interface YPbPr Pr GND Y GND Pb GND EZCamera Power & HD Video RJ-45 Connector Pin-outs The EZCamera Power and HD Video RJ-45 Connector is for use with either the Quick-Connect SR Interface or the Quick-Connect DVI/HDMI SR Interface ONLY (568B Wiring Standard).
TXD (to RXD of control source) No Flow control NOTE: The Vaddio ClearVIEW HD-19 Control Protocol is similar, but not identical to the Sony® VISCA™ command set in order to be compatible with several popular control devices. Not all VISCA commands are supported and there are many HD-19 specific commands in the following Command and Inquiry Lists.