Troubleshooting
4-1-2-3 Setting an indoor unit installation option(suitable for the condition of each installation location)
1. Check whether power is supplied or not.
- When the indoor unit is not plugged in, there should be additional power supply in the
indoor unit.
2. The panel(display ) should be connected to an indoor unit to receive option.
3. Set the installation option according to the installation condition of an air conditioner.
- The default setting of an indoor unit installation option is "02000-100000-200000-300000".
- Individual control of a remote controller(SEG20) is the function that controls an indoor unit
individually when there is more than one indoor unit.
4. Set the indoor unit option by wireless remote controller.
SEG1
SEG2
0
2
SEG7
SEG8
1
Drain pump
SEG13
SEG14
2
External control
SEG19
SEG20
Individual control of
3
a remote controller
1WAY/2WAY/4WAY MODEL : Drain pump(SEG8) will be set to 'USE + 3minute delay' even if the drain pump is set to 0.
1 WAY/2WAY/4WAY,DUCT MODEL : Number of hours using filter(SEG18) will be set to '1000hour' even if the SEG18 is set to exept for 2 or 6.
If you input a number other than 0~4 of the individual control of the indoor unit(SEG20), the indoor is set as "indoor 1".
Option No. : 02XXXX-1XXXXX-2XXXXX-3XXXXX
Option
SEG1
Explanation
PAGE
Remote
Controller
Display
Indication Details Indication
Indication
and Details
0
Option
SEG7
Explanation
PAGE
Use of drain pump
Remote
Controller
Display
Indication Details Indication
Indication
and Details
1
4-15
SEG3
RESERVED
Exterior temperature sensor
SEG9
Hot water heater
SEG15
External control
output
SEG21
EEV opening of an indoor
Heating setting
unit stopped during oil
compensation
return or Defrost operation.
SEG2
SEG3
Use of robot
MODE
cleaning
Details Indication
Details
0
Disuse
2
1
Use
SEG8
SEG9
Use of hot water
heater
Details Indication
Details
0
Disuse
0
Disuse
1
Use
1
Use
Use +
2
3minute
delay
SEG4
Central control
SEG10
SEG11
Opening the electronic
Electronic heater
expansion valve
SEG16
SEG17
S-Plasma ion
Buzzer
SEG22
SEG23
SEG4
Use of external
Use of central control
temperature sensor
Indication
Details Indication
0
Disuse
0
1
Use
1
SEG10
Opening the electronic
Use of electronic
expansion valve of an indoor unit
heater
when heating operation stops.
Indication
Details Indication
0
Disuse
0
1
Use
1
Indoor Unit
1(L)
F2
2(N)
F1
SEG5
SEG6
FAN RPM compensation
SEG12
Master / Slave
SEG18
Number of hours using
filter
SEG24
-
Human sensor
SEG5
SEG6
FAN RPM
compensation
Details
Indication
Details
0
Disuse
Disuse
RPM
1
compensation
High ceiling
Use
2
KIT
SEG11
SEG12
Master / Slave
Details
Indication
Details
0
0
slave
80
1
master
Samsung Electronics