features of your new

air conditioner

• Cool Summer Offer
On those hot sweltering summer days and long restless nights, there is no better escape
from the heat than the cool comforts of home. Your new air conditioner brings an end to
exhausting hot summer days and lets you rest. This summer, beat the heat with your own
air conditioner.
• Cost Efficient System
Your new air conditioner not only provides maximum cooling power in the summer, but can
also be an efficient heating method in the winter with the advanced "Heat pump" system.
This technology is up to 300% more efficient than electrical heating, so you can further
reduce its running cost. Now, meet year-round needs with one air conditioner.
• Flexible installation
Duct type air conditioner is designed to be slimmer and offers different solutions for any
shape room allowing for specific air flow requirements. Also, the air intake can be set up on
either the bottom or rear of the unit, so there is more flexibility in installation.
For easy future reference write the model and serial number
down. You will find your model number on the right side of
the air conditioner.
02_ features
Duct type_IB_E_29810-1.indd 2
Model #
Serial #
2008-11-12 16:28:00

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AVXDSH022EE and is the answer not in the manual?

Questions and answers

Summary of Contents for Samsung AVXDSH022EE

  • Page 1: Air Conditioner

    features of your new air conditioner • Cool Summer Offer On those hot sweltering summer days and long restless nights, there is no better escape from the heat than the cool comforts of home. Your new air conditioner brings an end to exhausting hot summer days and lets you rest.
  • Page 2: Safety Information

    Because the following operating instructions cover various models, the characteristics of your air conditioner may differ slightly from those described in this manual. If you have questions, call your nearest contact center or find help and information online at www.samsung.com. What the icons and signs in this user manual mean:...
  • Page 3 safety information SEVERE WARNING SIGNS If any gas or impurities other than R410A refrigerant come into the refrigerant pipe, serious problem may occur and it may cause injury. Do not spray flammable gases such as insecticide near the air conditioner. •...
  • Page 4: Caution Signs

    Install the supplied cables firmly. Fix them securely so that external force is not exerted to the terminal block. • If the connection is loose, heat may generate and cause electric shock or fire. Use a rated circuit breaker only. •...
  • Page 5 safety information CAUTION SIGNS Do not expose the dust filter to direct sunlight while drying. • Strong direct sunlight may deform the dust filter. Do not allow children to climb on the air conditioner. Use only rated accessories and install the air conditioner with rated equipments. •...
  • Page 6 Check for damage on delivery. If damaged, do not install the air conditioner and call the place of purchase immediately. Insert the dust filter before operating the air conditioner. • If there is no dust filter inside the air conditioner, accumulated dust may shorten the life of the air conditioner and cause electricity waste.
  • Page 7 safety information CAUTION SIGNS Make sure the voltage and frequency of the electric system are compatible with the air conditioner. If a power outage occurs while the air conditioner is working, turn off the power source immediately. Max current is measured according to IEC standard for safety and current is measured according to ISO standard for energy efficiency.
  • Page 8 contents VIEWING YOUR AIR CONDITIONER USING YOUR AIR CONDITIONER CLEANING AND MAINTAINING THE AIR CONDITIONER INSTALLING YOUR AIR CONDITIONER This product has been determined to be in compliance with the Low Voltage Directive (2006/95/EC), and the Electromagnetic Compatibility Directive (2004/108/EEC) of the European Union. (Applicable in the European Union and other European countries with separate collection systems) This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g.
  • Page 9: Viewing Your Air Conditioner

    viewing your air conditioner Congratulations on the purchase of the air conditioner. We hope you enjoy the features of your air conditioner and stay cool or warm with optimal efficiency. Please read the user manual to get started and to make the best use of the air conditioner. SLIM DUCT TYPE MA DUCT TYPE Your air conditioner may look slightly different from the illustration shown above depending...
  • Page 10: Tips On Using Your Air Conditioner

    using your air conditioner TIPS ON USING YOUR AIR CONDITIONER Here are some tips that you would follow when using your air conditioner. TOPIC Cooling Heating Frost & De-ice High indoor/outdoor temperatures Power failure Protection mechanism Duct type_IB_E_29810-1.indd 11 RECOMMENDATION •...
  • Page 11: Cleaning The Filter

    cleaning and maintaining the air conditioner For the best performance from your air conditioner, clean it periodically. When cleaning, make sure to unplug from the unit for user’s safety. CLEANING THE FILTER When cleaning the filter, make sure to unplug the power from the unit. Washable foam based Air filter captures large particles from the air.
  • Page 12: Ma Duct Type

    MA duct type 1. Slide out the Air filter on the rear side panel to the right side. 2. Clean the Air filter with a vacuum cleaner or soft brush. If dust is too heavy, then rinse it with running water and dry it in a ventilated area. •...
  • Page 13: Maintaining Your Air Conditioner

    cleaning and maintaining the air conditioner MAINTAINING YOUR AIR CONDITIONER If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition. 1. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and disconnect the power plug.
  • Page 14: Internal Protections Via The Unit Control System

    Internal protections via the unit control system This internal protection operates if an internal fault occurs in the air conditioner. Type Against cold air De-ice cycle Anti-protection of internal battery Protect compressor If the heat pump is operating in Heat mode, De-ice cycle is actuated to remove frost from an outdoor unit that may have deposited at low temperatures.
  • Page 15: Troubleshooting

    appendix TROUBLESHOOTING Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses. PROBLEM The air conditioner does not operate immediately after it has been restarted. The air conditioner does not work at all. The temperature does not change.
  • Page 16: Operation Ranges

    OPERATION RANGES The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use. OPERATIONAL TEMPERATURE MODE INDOOR COOLING 18˚C to 32˚C HEATING 27˚C or less DRYING 18˚C to 32˚C The standardized temperature for heating is 7˚C.
  • Page 17: Indoor Unit Installation

    Installation Part Indoor Unit Installation It is recommended to install the Y-joint before installing the indoor unit. Place the pattern sheet on the ceiling at the spot where you want to install the indoor unit. Note Since the diagram is made of paper, it may shrink or stretch slightly due to temperature or humidity.
  • Page 18: Drain Pipe And Drain Hose Installation

    Wind insulating tape around the pipes and drain hose avoiding to compress the insulation too much. Insulation cover pipe Insulation pipe Indoor unit Must fit tightly against  body without any gap. Be sure to overlap the insulation Finish wrapping insulating tape around the rest of the pipes leading to the outdoor unit.
  • Page 19: Wiring Work

    Drainpipe Connection Without the drain pump Install horizontal drainpipe with a slope of 1/100 or more and fix it by hanger space of 1.0~1.5m. Install U-trap at the end of the drainpipe to prevent a nasty smell to reach the indoor unit. Do not install the drainpipe to upward position.
  • Page 20: Additional Functions

    Indoor Unit Setting Before installing the indoor unit, assign an address to the indoor unit according to the air conditioning system plan. The address of the indoor unit is assigned by adjusting MAIN(SW01, SW02) and RMC(SW03, SW04) rotary switches. SW01 SW05 ...
  • Page 21 0900-SAMSUNG (0900-7267864) (€ 0,10/Min) 3 - SAMSUNG(7267864) 0 801 1SAMSUNG(172678) 022-607-93-33 80820-SAMSUNG(726-7864) 0800-SAMSUNG(726-7864) 902 - 1 - SAMSUNG (902 172 678) 075 - SAMSUNG(726 78 64) 0845 SAMSUNG (7267864) 0818 717 100 0810 - SAMSUNG(7267864, € 0.07/min) 0848 - SAMSUNG(7267864, CHF 0.08/min)
  • Page 22: User Manual

    Air Conditioner imagine Thank you for purchasing this Samsung product. To receive more complete service, please register your product at www.samsung.com/global/register Duct type_IB_E_29810-1.indd user manual the possibilities Duct Type Series Slim duct : AVXDS MA duct : AVXDU 2009-05-08 ソタタ・10:26:20...