DMX protocols

The tables below give control details for each individual LED in the EvenLED panel.
16-bit control
8-bit control*
*The EvenLED is supplied set up for 16-bit control by default. If you want to reconfigure panels for 8-bit
control, see "Configuring panels using a DMX controller" on page 21.

Software version and mode settings display

EvenLED panels show their software versions and mode settings when powered on if they are configured to
do so as described under "Configuring panels using a DMX controller" on page 21.
Software version display
EvenLED panels display their software as a binary
number on their LEDs. See Figure 13. The top row of
LEDs shows the tens and the second row down shows the
units (ones) in the version number. The bottom two rows
simply repeat the number displayed on the top two rows.
Software version display: example
See Figure 14. If a panel is running software version 29:
• 20 (LED 15) lights in the top row
• 1 and 8 (LEDs 9 and 12) light in the second row down
• 20 + (1 + 8) = 29
• The bottom two rows repeat the number displayed on
the top two rows.
20
Channel
Value
1
0 - 255
2
0 - 255
3
0 - 255
4
0 - 255
5
0 - 255
6
0 - 255
Channel
Value
1
0 - 255
2
0 - 255
3
0 - 255
EvenLED user manual
Percent
Function
Red
0 - 100%
Intensity 0
100%
Red (fine)
0 - 100%
Fine adjustment
Green
0 - 100%
Intensity 0
100%
Green (fine)
0 - 100%
Fine adjustment
Blue
0 - 100%
Intensity 0
100%
Blue (fine)
0 - 100%
Fine adjustment
Percent
Function
Red
0 - 100%
Intensity 0
100%
Green
0 - 100%
Intensity 0
100%
Blue
0 - 100%
Intensity 0
100%
80 40 20 10
8
80 40 20 10
8
Figure 13: Software version display
80 40 20 10
8
80 40 20 10
8
Figure 14: Software version 29
Start code = 0
Start code = 0
10s
4
2
1
1s
}
10s
Repeat of first
two rows
4
2
1
1s
10s
4
2
1
1s
}
10s
Repeat of first
two rows
4
2
1
1s