ZN-S100V/ZN-S1000VE HARDWARE MANUAL
Please pay attention to electric characteristics during installation.
(Detailed instructions are being prepared.)
1 2
5. RS‐485
The RS‐485 serial port consists of DATA+, DATA‐ and GND as following Figure 10.
6. RS‐232C
RS‐232C Terminal Block is used for some devices such as POS terminal block.
③ LAN Connector (Ethernet)
This is a RJ45 LAN connector for 10/100 Base‐T Ethernet. This socket can also be used to
power the ZN‐S100V/ZN‐S1000VE via PoE (Optional).
2010/2-1 D1A.02
ch1
ch2
GND
Figure 9. Digital Output Connection
DATA+
DATA‐
GND
+ ‐
Figure 10. RS‐485 Connection
RX
TX
GND
RX TX
Figure 11. RS‐232C Connection
LED 1
+12V
LED 2
DATA+
DATA‐
GND
PTZ Camera
TX
RX
GND
11