Drainage specifications

The drainage system must:
- be a siphon-type;
- have a one meter maximum length;
- have a minimum incline of 4%;
- have a diameter that is NOT less than the drain pipe attachment;
- be dedicated to each appliance; if this is not the case, make sure that the main drainage pipe is sized sufficiently
to ensure that water flows away properly without any problems;
- be free of kinks.
L= max 1 m
L= min 30 cm
L= min 30 cm
L= max 1 m

Plumbing: interventions

L= min 30 cm
min 4°
L= max 1 m
25 mm
L= min 30 cm
L= max 1 m
min 4°
25 mm
ChefTop
min 4°
min
min 4°
min
If it is necessary to disconnect the "quick cou-
pling" attachments, such as for maintenance
or to install an accessory, use the wrench sup-
compromise the seal.
35
BakerTop
min 4°
L= min 30 cm
L= max 1 m
min
25 mm
L= min 30 cm
L= max 1 m
min 4°
min
25 mm