No.
Item
14
Central control
1) Setting at the central controller side enables to select
mode selection
2) RBC-AMT21
15
Energy-save
1) Selecting [AUTO] mode enables an energy-saving to
control
(By connected
2) The setup temperature is shifted (corrected) in the
outdoor unit)
3) Data (Input value room temp. Ta, Outside temp. To, Air
4) The setup temperature is shifted every 20 minutes,
16
Max. frequency
1) This control is operated by selecting [AUTO] opera-
cut control
2) COOL operation mode: the frequency is controlled
3) HEAT operation mode: the frequency is controlled
17
DC motor
1) When the fan operation has started, positioning of the
(For 4-way air
discharge
cassette type
2) The motor operates according to the command from
only)
NOTES :
• When the fan rotates while the air conditioner stops
• When a fan locking is found, the air conditioner stops,
Outline of specifications
the contents which can be operated on the remote
controller at indoor unit side.
[Last push priority] :
The operation contents can be selected from both
remote controller and central controller of the indoor
unit side, and the operation is performed with the
contents selected at the last.
[Center] :
Start/Stop operation only can be handled on the
remote controller at indoor unit side.
[Operation Prohibited] :
It cannot be operated on the remote controller at
indoor unit side. (Stop status is held.)
be operated.
range not to lose the comfort ability according to input
values of various sensors.
volume, Indoor heat exchanger sensor temp. Tc) for
20 minutes are taken the average to calculate
correction value of the setup temperature.
and the shifted range is as follows.
In cooling time : +1.5 to –1.0K
In heating time : –1.5 to +1.0K
tion mode.
according to
Ta( C) Normal control
the following
+4
figure if
To < 28°C.
+3
Tsc
according to
Ta( C)
the right
Tsh
figure if
To > 15°C.
–3
–4
Normal control
stator and the rotor are performed.
(Moves slightly with tap sound)
the indoor controller.
due to entering of outside air, etc, the air conditioner
may operated while the fan motor stops.
and an error is displayed.
www.ilmalämpöpumput.com
Max. frequency is restricted
to approximately the rated
cooling frequency
Max. frequency is restricted
to approximately the rated
heating frequency
– 45 –
Remarks
(No display)
[CENTER] goes on.
[CENTER] goes on.
In a case of wireless type, the
display lamp does not change.
However, contents which can be
operated are same.
The status set in [CENTER]/
[Operation Prohibited] mode is
notified with the receiving sound
"Pi, Pi, Pi, Pi, Pi" (5 times).
Check code [P12]