Toshiban lämmitys- ja jäähdytyslaitteiden jälleenmyyjä pääkaupunkiseudulla on Jäähdytinpalvelu RefGroup Oy
No.
Part name
Electric parts
6) Take off fixing screw (1 position) of the electric
box assembly
7) Pull out Tc sensor and Tcj sensor from sensor
8) After replacement of the parts, set a trap so that
ƒ
Side grille
1) Remove shaft of the side grille from the air
Heat exchanger
1) Perform work of item
2) Remove pipe holder at rear side of the main
3) Take off fixing screws (2 pcs.) at the left side of
4) Take off two fixing screws of the heat exchanger
5) Take off fixing screw at lower right side of the
6) Remove the heat exchanger from the rear main
Procedure
parts base, and then pull out the electric parts
base toward you.
holder of the heat exchanger. After replacement
of the parts, incorporate two sensors without
mistake as shown in the right figure.
(Tube is attached to Tcj sensor.)
water does not enter in the electric parts assem-
bly. (Incomplete process for lead wires may
cause water leak.)
conditioner body. (First remove the left shaft and
then other shafts while sliding the side grille left
and right.)
.
body.
the end plate of the heat exchanger.
holder (right), and then remove the heat ex-
changer holder (right).
heat exchanger.
body by lifting it upward.
www.ilmalämpöpumput.com
Fixing screw
– 148 –
Remarks
Tjc sensor position
(Tube is attached to Tcj sensor.)
TC sensor
position
Pipe
holder
FFFixing
Fixing
screw
screw
Fixing
screw

Hide quick links: