Toshiba RAV-SM560AT-E Service Manual page 145

Toshiba hfc r410a split type air conditioners service manual
Hide thumbs Also See for RAV-SM560AT-E:
Table of Contents

Advertisement

Toshiban lämmitys- ja jäähdytyslaitteiden jälleenmyyjä pääkaupunkiseudulla on Jäähdytinpalvelu RefGroup Oy
AID-P710BH, P800BH, P1120BH
Be sure to turn off the power supply before disassembling work.
No.
Item
1
Electric parts box
2
Fan
3
Drain pan
4
Heat exchanger
5
TC sensor
(Sensor side)
Procedure
1) Remove the electric parts box.
(Supplement: Refer to How to remove
the electric parts box.)
In this time, remove connectors of TA
sensor, TC sensor, and TCJ sensor, if
necessary.)
1) Remove connector of the fan motor.
2) Using a hexagonal wrench, loosen
coupling fixing screws at 2 positions,
and then slide the fan motor to reverse
side.
3) Remove set screws (6 positions) of the
fan case (left).
4) Remove fan motor mounting metal
(screws at 2 positions) while holding
the fan motor with hands.
5) Remove capacitor fixing screw
(1 position).
6) Take down the fan motor and the fan
case (left).
7) Loosen set screw of the Silocco fan.
8) Replace the fan motor.
1) Take down the indoor unit and then
treat the drain pan on the floor.
2) Remove screws fixing the drain pan
and then replace the drain pan.
1) Take down the indoor unit and then
treat the heat exchanger on the floor.
2) Remove screws fixing the drain pan
and then remove the drain pan.
3) Remove the shielding plate. (Screws at
4 positions)
4) Remove screws (at 5 positions) fixing
the heat exchanger, and then replace
the heat exchanger.
1) Remove the check port cover.
2) Remove the shielding plate.
(At 4 positions)
3) Pull out the sensors inserted into pipe
of the heat exchanger.
www.ilmalämpöpumput.com
Fan case (left)
Shielding plate
Check port
cover
– 145 –
Electric parts
fixing screw
Electric
parts box
Capacitor
Silocco
fan (right)
Fan motor
Drain pan
Shielding plate
Heat exchanger

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents