3-13-2 Auto signal level
LT
When n is set to 1 or higher, the AR2300 sends s meter level in above preset
interval.
To read: LT <CR>
LTnnnn
Response:
3-14 Audio recorder control
3-14-1 Control relay status
TP
The relay contact is available at the ACC1 connector to control an external audio
recorder device. When the squelch is open, the relay contact will close.
When squelch is closed, then the relay contact will open.
To read: TP <CR>
TPn
Response:
3-14-2 Control relay status report
TC
When the control relay opens or close during receive, the relay operation status
will be output by the TP command if the TC command is set to on.
No report will be made if the TC command is set to 0.
To read: TC <CR>
TCn
Response:
3-15 Manual RF gain
This command is available only when the AGC is set to 3 (manual mode).
RG
RGnnn
To read: RG <CR>
RG nnn
Response:
29
LTnnnn
TPn
TCn
(nnn: 000 – 110) (in dB)
n: 0 or 1 ~ 6000 (in approximately 10 mS)
0: Off
(default)
n: 0 , 1
0: Off (Relay contact open) (default)
1: On (relay contact closed)
n: 0 , 1
0: Off (No report) (default)
1: On (Report by the TP command)
(default::110)