6.3
CAUTION
Make sure pump and motor turn freely, especially after extended periods of
downtime. To do this put a screwdriver into the slot at the fan end and turn it by
hand in the direction of rotation. If necessary remove the fan cover and turn the
fan by hand. After re-starting make sure the mechanical seal doesn't leak.
6.4
CAUTION
Never operate the pump without the strainer basket (143), otherwise the pump
may get clogged and blocked.
6.5
CAUTION
When starting a pump with three-phase current motor for the first time, make
sure the motor turns in the direction of the affixed arrow (anticlockwise, seen
from the fan). If the motor rotates in the wrong direction, two phases must be
switched (by a licensed electrician only!). If the direction of rotation is wrong,
the pump is noisier and primes less.
6.6
CAUTION
Please make sure that the installed shutoff valves in the suction and pressure
lines are completely open. The pump must never run with shutoff valves closed!
7.
Maintenance / Repair
CAUTION
The strainer basket (143) must be periodically emptied. A full or dirty strainer
will impair the pump's flow rate and the filtration.
7.1 Cleaning the strainer
1. Shut down pump.
2. Close shutoff valves.
3. Open ring nut (160.2), see par. 6.1.
Lift transparent lid (160.1).
Remove strainer basket (143), clean and replace it.
Put transparent lid (160.1) back in place and tighten ring nut (160.2), see
par. 6.1 and 6.3.
4. Open shutoff valves.
5. Restart pump.