EWM Pico 162 Operating Instructions Manual page 25

Table of Contents

Advertisement

Tighten the pressure regulator screw connection on the gas bottle valve to be gas-tight.
Screw the shielding gas connection of the welding torch to the pressure reducer on the shielding gas
cylinder.
Slowly open the gas cylinder valve.
Open the rotating valve on the welding torch
Before each welding process, the rotating valve must be opened; after the welding process, it
must be closed.
Set the required amount of shielding gas on the pressure reducer, about 4 - 15 l/min depending on the
current strength and the material.
099-002040-EW501
28.04.2014
Design and function
TIG welding
25