Zephyr Titan Island AK7736AS Use, Care And Installation Manual

Hide thumbs Also See for Titan Island AK7736AS:

Advertisement

Available languages

Available languages

Quick Links

Titan Island
AK7736AS
AK7742AS
AK7748AS
Model number:
Serial Number:
SEP19.0101 © Zephyr Ventilation, LLC
www.zephyronline.com
C
+
Airflow Control Technology
TM

Advertisement

loading

Summary of Contents for Zephyr Titan Island AK7736AS

  • Page 1 Titan Island AK7736AS AK7742AS AK7748AS Model number: Airflow Control Technology Serial Number: SEP19.0101 © Zephyr Ventilation, LLC...
  • Page 2 www.zephyronline.com...
  • Page 3 SAFETY NOTICE ..............LIST OF MATERIALS ............INSTALLATION Ducting Calculation Sheet ........Mounting Height & Clearance ........ Ducting Options ............Hood Specifications ........... Mounting the Hood 9-11 ............. PBD-1300A Dual Blower Ducting ......FEATURES & CONTROLS Electronic LCD Controls ......... 13 Optional Remote Control........
  • Page 4 www.zephyronline.com READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.
  • Page 5 AK7748AS - 299 Watts, 4.2 Amps Power consumption shown above is the default power specs. Hoods with Zephyr’s proprietary Airflow Control Technology (ACT) enabled will consume less power. See wiring diagram at the end of this manual for more information.
  • Page 6 www.zephyronline.com www.zephyronline.com www.zephyronline.com MODELS: AK7736AS, AK7742AS, AK7748AS PARTS SUPPLIED 1 - Hood 4 - Duct covers, 2 upper & 2 lower 2 - Support frames, 1 upper & 1 lower 2- Angled support brackets 1- Middle support frame 4 - Baffle filters, AK7736AS & AK7742AS 6 - Baffle filters, AK7748AS 2 - LED light bulbs, AK7736AS &...
  • Page 7 Equivalent number Duct pieces Equivalent number Duct pieces length x used T otal length x used T otal 3- 1/ 4” x 10” 1 Ft. 3- 1/ 4” x 10” 5 Ft. Rect., Rect. to straight 6” round transition 6”, 7”, 8”, 10” 1 Ft.
  • Page 8 www.zephyronline.com ALWAYS, when possible, reduce the number or transitions and turns. If long duct run is required, increase duct size. If turns or transitions are required; install as far away from hood duct output and as far apart, between the two as possible. Minimum mount height between range top to hood x .
  • Page 9 WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use rigid metal ductwork only. Fasten all connections with sheet metal screws and tape all joints with certified Aluminum Tape or Duct Tape. Some Ducting Options Roof Pitch w/ Flashing &...
  • Page 10 www.zephyronline.com ” Standard Min. - 33” Max. - 50“ ” (36”, 42“) 15/16 Z1C-0077 (36”, 42“) (48”) 5/8” Z1C-0177 (48”) Min. - 49” Max. - 78” ” (36”) 15/16 ” (42”) 15/16” (48”) 15/16” SIDE FRONT ” (36”, 42“) (48”) 15/16”...
  • Page 11 CAUTION: At least two installers are required due to the weight and size of the hood. FRONT Ceiling Joists Wood Blocking Cut-Out Shaded Area XP022220 Top Support Frame FIG. B Support Frame Arm Bottom Support Frame Mounting Screws (pre-installed) Hood Body FIG.
  • Page 12 www.zephyronline.com Duct Cover Standard Frame Top Support Frame Assembly Instructions FIG. F FIG. D Bottom Support Frame (secures to top of blower housing) back Key Holes front - facing controls FIG. C FIG. E 3. Attach square support bracket inside the support frame assembly. The placement of the square support bracket should preferably be aligned in the middle where the top and bottom frame intersect (FIG.
  • Page 13 Top Support Frame Top Duct Covers Cable Lock A cable locking connector (not supplied) might be required by local codes. Check with local requirements and codes, purchase and install appropriate connector if necessary. Bottom Duct Covers Cable Lock Bottom Support Frame FIG.
  • Page 14 www.zephyronline.com This range hood is equipped standard with a single blower vertical duct option. To convert from single blower vertical ducting to dual blower vertical ducting please following the instructions below. 1. Disconnect blower plug and white and black 2. Remove (4) screws from interior of hood body power cables.
  • Page 15 Power / Delay Off Display Adjust 6 Speed Levels Lights On/Dim/Off 1. Power / Delay Off Power Button Function On/Off button will turn power on and off for entire hood (fan and lights). The hood will remember the last speed and light level it was turned off at.
  • Page 16 The RF remote control is equipped with a magnet on the back for easy storage. The remote may be placed on any magnetic surface such as a refrigerator or the Zephyr remote holder, FIG. 1. The remote holder can be inserted into a standard electrical outlet for easy storage. Note: The remote holder does not charge the RF remote.
  • Page 17 Directional Lighting The light bulbs can be tilted forwards and backwards to better direct light over your cooking surface. FIG. J. Replacement bulbs are available to purchase directly from Zephyr. Purchase online at http://store.zephyronline.com or call us at 1.888.880.8368 FIG. I...
  • Page 18 www.zephyronline.com TROUBLESHOOTING PROCEDURES Issue Cause What to do After installation, 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s the unit doesn’t power is ON. work. 2. The power line and the cable locking connector 2.
  • Page 19 Some local codes limit the maximum amount of CFM a range hood can move. ACT™ allows you to control the maximum blower CFM of select Zephyr Ventilation range hoods without the need for expensive make up air kits. ACT™ enables the installer to easily set the maximum blower speed to one of two most commonly specified CFM levels;...
  • Page 20 www.zephyronline.com ACT 590 CFM - Fan Max. 175W @ 2.6A ACT 390 CFM - Fan Max. 94W @ 1.4A ACT 290 CFM - Fan Max. 63W @ 0.9A...
  • Page 21 DESCRIPTION PART# Replacement Parts LED Light Bulb MR16 (GU10) 6W (each) Z0B0040 Baffle Filter (each) 50210036 Optional Accessories Duct Cover Extension (36”, 42”) Z1C-0077 Duct Cover Extension (48”) Z1C-0177 Dual Internal Blower PBD-1300A Make-Up Air Kit (Single Blower) MUA008A Make-Up Air Kit (Dual Blower) MUA010A To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8368...
  • Page 22 Zephyr Ventilation, LLC (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or workmanship as follows:...
  • Page 23 PRODUCT REGISTRATION Congratulations on the purchase of your Zephyr product! Please take a moment to register your new Zephyr product at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes.
  • Page 24 Titan Island AK7736AS AK7742AS AK7748AS Numéro de modèle : Numéro de série : Date d’achat : Détaillant: SEP19.0101 © Zephyr Ventilation LLC. LISEZ ET CONSERVEZ CES INSTRUCTIONS...
  • Page 25 www.zephyronline.com...
  • Page 26 MISE EN GARDE DE SÉCURITÉ ... 2-3 ..............LISTE DU MATÉRIEL ......................INSTALLATION Feuille de calcul pour le conduit .................. Espace libre et hauteur de montage ................. Options d’installation pour le conduit ................ Spécifications ........................Installation de la hotte... 9-11 ....................
  • Page 27 www.zephyronline.com LISEZ ET CONSERVEZ CES INSTRUCTIONS AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE OU DE DÉCHARGE ÉLECTRIQUE, N’UTILISEZ PAS CET APPAREIL AVEC UN TABLEAU DE COMMANDE À SEMI-CONDUCTEURS. AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE, DE DÉCHARGE ÉLECTRIQUE OU DE BLESSURE, RESPECTEZ CES CONSIGNES : a.
  • Page 28 ATTENTION POUR RÉDUIRE LES RISQUES D’INCENDIE, N’UTILISEZ QUE DES CONDUITS D’AÉRATION EN MÉTAL. ATTENTION Pour réduire les risques d’incendie et pour évacuer l’air convenablement, assurez-vous de canaliser l’air à l’extérieur de la maison. N’installez pas l’échappement du conduit dans les espaces entre les murs, le plafond, le grenier, les vides sanitaires ou le garage.
  • Page 29 www.zephyronline.com www.zephyronline.com www.zephyronline.com MODELS: AK7736AS, AK7742AS, AK7748AS PARTS SUPPLIED 1 - Hood 4 - Duct covers, 2 upper & 2 lower 2 - Support frames, 1 upper & 1 lower 2- Angled support brackets 1- Middle support frame 4 - Baffle filters, AK7736AS & AK7742AS 6 - Baffle filters, AK7748AS 2 - LED light bulbs, AK7736AS &...
  • Page 30 Longueur x Pièces de conduit Longueur x Pièces de conduit T otal T otal Nombre utilisé Nombre utilisé 3- 1/ 4” x 10” 1 pi 6” circ. à 5 pi rect., droit rect. de 3-1/4" x 10" 6”, 7”, 8”, 10” 1 pi 6”...
  • Page 31 www.zephyronline.com adaptateurs sont nécessaires, installez-les le plus loin possible de l’ouverture et le plus éloigné possible l’un de l’autre. La hauteur de montage de la surface de la cuisinière au bas de la hotte ne devrait pas être inférieure à 24”. La hauteur de montage maximale ne devrait pas outrepasser 36”.
  • Page 32 AVERTISSEMENT DE RISQUE D’INCENDIE N’évacuez ou ne terminez JAMAIS l’échappement du conduit dans les espaces entre les murs, les vides sanitaires, le plafond, le grenier, ou le garage. Tous les échappements doivent être dirigés à l’extérieur de la maison. N’utilisez que des conduits en métal pour cloison simple. Fixez toutes les pièces du conduit avec des vis à...
  • Page 33 www.zephyronline.com ” Standard Min. - 33” Max. - 50“ ” (36”, 42“) 15/16 Z1C-0077 (36”, 42“) (48”) 5/8” Z1C-0177 (48”) Min. - 49” Max. - 78” ” (36”) 15/16 ” (42”) 15/16” (48”) 15/16” DEVANT CÔTÉ ” (36”, 42“) (48”) 15/16”...
  • Page 34 ATTENTION : Compte tenu du poids et des dimensions de la hotte, au moins deux installateurs sont nécessaires. DEVANT Solives de plafond Bloc de bois Zone de découpage ombragée XP022220 Cadre de fixation supérieur FIG. B Bras du cadre de fixation Cadre de fixation inférieur Vis de montage...
  • Page 35 www.zephyronline.com Couvercle des conduits Instructions Cadre de support supérieur d'assemblage du cadre standard FIG. F FIG. D Cadre de fixation inférieur (est fixé à la partie supérieure du boîtier du ventilateur) Encoches en trou Devant – commandes à l’avant FIG. C FIG.
  • Page 36 Cadre de fixation supérieur Pièces de recouvrement Raccord de câble supérieures Un raccord de câble (non inclus) pourrait également être exigé par les normes et réglementations locales. Informez-vous des exigences et des normes locales. Achetez et installez le connecteur approprié si nécessaire.
  • Page 37 www.zephyronline.com Cette hotte standard est munie d’une entrée pour conduit vertical avec un ventilateur simple. Pour la convertir d’un conduit vertical à ventilateur simple à un conduit vertical à ventilateur double, veuillez suivre les instructions ci-dessous. 2. Enlevez les quatre (4) vis de l’intérieur de la 1.
  • Page 38 Mise en marche/Arrêt à retardement Tableau d’affichage Sélection de la vitesse Lumières - Allumer/Veilleuse/Éteindre 1. Mise en marche/Arrêt à retardement Fonction de mise en marche La touche On/Off permet d’allumer et d’éteindre toutes les fonctions de la hotte (ventilateur et lumières). Lorsqu’elle est éteinte, la hotte garde en mémoire la dernière vitesse du ventilateur et le dernier réglage d’intensité...
  • Page 39 La commande à distance radioélectrique est munie d’un aimant pour un entreposage facile. La commande peut être mise sur n’importe quelle surface magnétique, comme un réfrigérateur ou le support à commande Zephyr (FIG. 1). Le support à commande peut s’installer à une prise électrique standard pour un rechargement facile.
  • Page 40 Les ampoules peuvent être inclinées vers l’avant et vers l’arrière pour mieux diriger la lumière sur votre surface de cuisson (FIG. J). Les ampoules de rechange sont disponibles à l’achat directement auprès de Zephyr. Achetez en ligne à http://store. zephyronline.com ou appelez-nous au 1.888.880.8368 FIG.
  • Page 41 www.zephyronline.com Procédures de Dépannage Problème Cause Solution Après 1. Le bloc d’alimentation n’est pas allumé 1. Assurez-vous que l’alimentation du disjoncteur l’installation, et de l’appareil est allumée l’appareil ne 2. La ligne électrique et le raccord de câble ne sont 2.
  • Page 42 /min qu’une hotte peut extraire. La ACT™ permet de contrôler la quantité maximale de pi /min qu’évacuent un éventail de hottes Zephyr, éliminant la nécessité d’acheter un dispositif d’air d’appoint dispendieux. La ACT™ permet à l’installateur d’ajuster facilement la vitesse maximale du ventilateur à...
  • Page 43 www.zephyronline.com Modèles: AK7736AS, AK7742AS Voltage: 120V 60HZ 4A Consommation D’énergie Total: 286W Ampoule: 13W Ventilateur: 273W NOIR BLANC Thermiquement Protégé Modèles: AK7748AS Voltage: 120V 60HZ 4.2A Consommation D’énergie Total: 299W Ampoule: 26W Ventilateur: 273W NOIR BLANC Thermiquement Protégé ACT 590 pi /min —...
  • Page 44 DESCRIPTION PART # Pièces de remplacement Ampoule MR16 (GU10) 6W (unité) Z0B0040 Filtre déflecteur (unité) 50210036 Accessoires Optionnels Recouvrement de conduit (36”, 42”) Z1C-0077 Recouvrement de conduit (48”) Z1C-0177 Ventilateur interne double PBD-1300A Clapet universel d’air compensation ventilaeur double MUA008A Clapet universel d’air compensation ventilaeur simple MUA010A Pour commander des pièces, visitez-nous en ligne au www.zephyronline.com ou communiquez avec...
  • Page 45 Zephyr Ventilation, LLC (désigné aux présentes sous le nom de « nous ») garantit au premier acheteur (désigné aux présentes sous le nom de « vous » ou « votre ») de produits Zephyr (les « Produits ») que lesdits produits sont exempts de défauts de fabrication ou de main-d’œuvre selon les conditions suivantes :...
  • Page 46 ENREGISTRMENT DU PRODUIT Nous vous félicitons d’avoir acheté une produit Zephyr. Veuillez prendre un moment pour enregistrer votre nouvelle produit au www.zephyronline.com/registration C’EST IMPORTANT Cet enregistrement rapide est utile à bien des égards. Il assure la couverture de votre garantie si vous avez besoin de service après-vente.

This manual is also suitable for:

Titan island ak7742asTitan island ak7748as