Connecting The Ac Supply; Figure 2.8 - System Wiring, Dual Configuration With "Y" Input - AE Techron 8101 Operator's Manual

Advanced switch-mode design power supply amplifier for pulse or continuous duty operation
Table of Contents

Advertisement

8101 OPERATOR'S MANUAL
2.6.3 Dual Configuration with "Y" Input
This configuration feeds a mono signal to both Channel 1 and Channel 2.
INPUTS: Connect the signal to the Channel 1 input. On the back panel, set the "Y" Input Switch to ON.
OUTPUTS: Connect the Channel 1 LOAD's positive (+) lead to Channel 1 positive terminal of amp; repeat for
negative (–). Connect the Channel 2 LOAD's positive (+) lead to Channel 2 positive terminal of amp; repeat
for negative (–).
See Figure 2.8. Turn up both Input Attenuators and set the Mode Switch to DUAL.
NOTE: When the "Y" Input Switch is on, the Channel 2 input can be used to daisy-chain to another amplifier.
NOTE: Always route the input and output wires in separate bundles.

2.7 Connecting the AC Supply

On the back panel, check whether your amplifier is labeled for 120V or 220-240V AC mains. Connect your
amplifier to the corresponding AC mains power source (power outlet) with the supplied AC power cord set.
The third prong of this connector (ground) is
an important safety feature. Do not attempt to
disable this ground connection by using an
adapter or other methods.
required AC mains voltage and frequency. The AC mains voltage must be no more than 15% above the
10
Figure 2.8 – System Wiring, Dual Configuration with "Y" Input
First connect the IEC end of the cord set to the IEC connector
on the amplifier. Then, with the amplifier in the OFF position,
plug the other end of the cord set into the AC mains.
Amplifiers don't create energy. The AC mains voltage and
current must be sufficient to deliver the power you expect.
Check the amplifier's back-panel label, which specifies the
Information subject to change