SensorNet/Manchester Line Termination
SensorNet and Manchester communication
protocols require that the dome furthest from the
video controller or junction box be terminated.
Looking through the hole in the top of the dome,
ensure switch S1 is set to "terminated" for the
dome furthest from the video controller or junction
box. All other domes should be "un-terminated".

Setting the Camera Address

Accessed through the hole in the top of the dome
are rotary switches SW1, SW2, and SW3. The
address range for SensorNet is 001 to 255. The
address range for Manchester is 0 to 64.
For example, for address 107, set SW3 to 1, SW2
to 0 (black dot), and SW1 to 7.
Compatibility with the VM96 Controller
If using a VM96 controller, the controller must be
Version 5.2 or higher.
SPEEDDOME OPTIMA LT INDOOR CAMERA DOME INSTALLATION AND SERVICE GUIDE (8200-0181-01, REV. C)
Power-Up Routine
After power is connected to the dome, the dome
performs a homing routine. During the homing
process, the camera will pan and then either:
· Go to the start point of the "apple peel" pattern,
or
· If powered up once before, to the last position in
memory.
Once the camera stops, the camera is online and
is ready to be controlled.

Synchronizing Domes

To prevent picture rolling when switching from
camera to camera, all domes can be synchronized
to the ac source. A V-phase adjustment at the
control console enables the dome to sync to any
line phase.

Save Packaging Material

Should the camera dome need to be sent to a
repair center, use the packaging that the dome was
shipped in.