SECTION 10 –
SLIDEOUT ROOMS AND LEVELING
Slideout
Cover-Awning
Also, freezing rain and snow can prevent the
slideout cover-awning (if equipped) from closing
and may cause damage to the cover-awning,
slideout room, weather seals and mechanisms.
To avoid potential damage, we recommend
retracting your slideout room during extreme
weather conditions.
SLIDEOUT ROOM
TROUBLESHOOTING –
ELECTRIC
Battery Voltage or Circuit Breaker
Problems
If the slideout room will not work:
Τhe chassis battery may be low on charge.
Press and hold the Battery Boost switch on the
dash while pressing the slideout control
switch. This momentarily connects the house
batteries to assist in retracting the room.
The circuit breaker may be tripped. The
circuit breaker, labeled 'Slideout Power' is
located on a panel on an interior wall of the
passenger side storage compartment just
behind or ahead of the entrance door.
Problems Retracting the Room
Set the Park Brake if the red Park Brake light
flashes while pressing the Retract button.
10-4
Green light will flash error code
if system malfunctions*
Diagnostics
Reset Button*
*Not equipped on single mechanism systems
If an error is detected on your DigiSync Room
Slide System, the green LED on the left side of
the control panel will blink an error code. If an
error code appears, see the On Board diagnostics
section to determine the problem. The error code
must be cleared prior to operating the room. To
clear the error, press the "RESET" button with a
small tool such as a toothpick. Before operating
the room after an error has been detected, check
for obvious faults such as obstructions prior to
trying to operate the room again. If the error code
appears again, the room will need to be retracted
using either the manual retraction method or the
fully manual method. Both methods listed below
are intended as a means to retract the room to
prepare the coach for travel to the nearest
authorized Service Center.
To retract the room after an error is detected,
you override the synchronization programming
and operate the room in the Manual Mode.
Manual Mode:
Manual Mode lets you individually move the
two room arms by pressing the IN and OUT
buttons on the control pad. This mode can be used
only if there is not a motor failure or full
electrical system failure. To override the encoder
and enter the Manual Mode, press and hold the
RESET button until the two LEDs begin to flash.
Red light will flash if
park brake not set.