Troubleshooting - Permobil Chairman Operator's Manual

Hide thumbs Also See for Chairman:
Table of Contents

Advertisement

Troubleshooting

Battery voltage indicator
The battery voltage indicator shows the status of the wheelchair.
Permanently on
Everything is working correctly.
Flashing slowly
The batteries need to be charged.
Flashing quickly
Fault signal. A fault has occurred and the wheelchair can not be driven.
Fault signals
The number of flashing lights indicates the fault.
Note the number of flashing lights.
Switch off the chair.
Switch the chair back on.
If the fault is still there, count the number of flashing lights, then look up the possible cause and
action in the table below..
CAUSE
High battery voltage
Break in the brake circuit
Fault in the electronics
Fault in the control panel
Short circuit, right drive motor
Open circuit, right drive motor
Short circuit, left drive motor
Open circuit, left drive motor
Low battery voltage
LEDs
Check the battery and the connections
10
between the battery and control Inuit.
9
Check the connections to the magnetic brake.
Check the connections to the output stage.
8
If the fault persists, change the output stage.
Make sure the joystick isn't actuated at switch-
7
on, change the control panel.
6
5
Check the motor connections and cable.
Check the connection to the right drive
4
motor. Check whether the drive motor
brushes are worn.
3
Check the motor connections and cable.
2
Check the connection to the left drive motor.
Check the condition of the battery. Check the
1
connection between the battery and the control unit.
25
Troubleshooting
ACTION

Advertisement

Table of Contents
loading

Table of Contents