In the example below, the white box is the centering window. The centering window has been set to 20% left, 30% right,
8% top, and 25% bottom. Since Bar Code 1 passes through the centering window, it will be read. Bar Code 2 does not
pass through the centering window, so it will not be read.
Note: A bar code needs only to be touched by the centering window in order to be read. It does not need to pass completely
through the centering window.
Scan Presentation Centering On, then scan one of the following bar codes to change the top, bottom, left, or right of the
centering window. Then scan the percent you want to shift the centering window using digits on the inside back cover of
this manual. Scan Save. Default Presentation Centering = 40% for Top and Left, 60% for Bottom and Right.
Presentation Centering On
Top of Presentation Centering
Window
0%
Bar Code 1
10
20
30
40
50
60
70
80
90
100
0
10
20
30
Bar Code 2
40
50
60
70
80
90
100%
* Presentation Centering Off
Bottom of Presentation
Centering Window