Changing a Cordless Scanner Battery

1. Use the hinged wire or a flat head screwdriver to remove the screw from the
end cap.
2. Remove the end cap and remove the battery from the handle.
3. Insert replacement battery.
4. Replace end cap and screw it back on.

Troubleshooting a Corded Scanner

The scanner automatically performs self-tests whenever you turn it on. If your
scanner is not functioning properly, review the following Troubleshooting Guide to
try to isolate the problem.
Is the power on? Is the aimer on?
If the aimer isn't illuminated, check that:
• The cable is connected properly.
• The host system power is on (if external power isn't used).
• The trigger works.
Is the scanner having trouble reading your symbols?
If the scanner isn't reading symbols well, check that the scanner window is clean and that the symbols:
• Aren't smeared, rough, scratched, or exhibiting voids.
• Aren't coated with frost or water droplets on the surface.
• Are enabled in the scanner or in the decoder to which the scanner connects.
Is the bar code displayed but not entered?
The bar code is displayed on the host device correctly, but you still have to press a key to enter it (the Enter/Return key or
the Tab key, for example).
• You need to program a suffix. Programming a suffix enables the scanner to output the bar code data plus the key you
need (such as "CR") to enter the data into your application. Refer to
further information.
Does the scanner read the bar code incorrectly?
If the scanner reads a bar code, but the data is not displayed correctly on the host screen:
• The scanner may not be programmed for the appropriate terminal interface.
For example, you scan "12345" and the host displays "@es%."
Reprogram the scanner with the correct Plug and Play bar code. See
• The scanner may not be programmed to output your bar code data properly.
For example, you scan "12345" and the host displays "A12345B."
Reprogram the scanner with the proper symbology selections. See
The scanner won't read your bar code at all.
1. Scan the sample bar codes in the back of this manual. If the scanner reads the sample bar codes, check that your bar
code is readable.
Verify that your bar code symbology is enabled (see
If the scanner still can't read the sample bar codes, scan
If you aren't sure what programming options have been set in the scanner, or if you want the factory default settings
restored, refer to
Resetting the Custom Defaults

Troubleshooting a Cordless System

Troubleshooting a Base

Note: Visit the Services and Support section of our website (www.honeywellaidc.com) to check for the latest software for
both the scanner and the base.
Prefix/Suffix Overview
Programming the Interface
Chapter
Chapter
7).
All Symbologies
(page 7-1).
on page 10-3.
End Cap
beginning on page 5-1 for
beginning on page 2-1.
7.
12 - 3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Voyager 1452g series145*g1d145*g2d

Table of Contents