H
M
I
EARTH
OUNT
NSTALLATION
Clean-out tee
Fresh-air intake should com
from chimney. If holes
already exist fresh-air intake
can be taken through back
of the fireplace or through
the ash dump.
Figure 17: Hearth Mount - Side View.
1. Lock fireplace damper in the open
position.
2. Install flexible stainless steel liner or listed
pellet vent to the top of the chimney.
All joints in the exhaust venting system
must be fastened with at least three (3)
screws.
3. Install a sealing plate at the top of the
chimney.
4. Connect a rain cap and flex adapter to the
chimney liner/pipe.
5. Connect a clean-out tee or a 90° elbow to
the liner/pipe.
6. Install tee onto stove.
18
Installation
:
Masonry Fireplace
Damper Removed
or Fastened Open
Mantel
Minimum (8") 200mm
from top of stove
Min (6")
150mm
Floor
Protection
Combustible Floor
Figure 18: Hearth Mount - Over View.
Hampton GC60 Cast Pellet Stove Technical Manual