Outside Vertical Installations - HAMPTON BAY GC60 Technical Manual

Freestanding cast iron pellet stove
Hide thumbs Also See for GC60:
Table of Contents

Advertisement

O
V
I
UTSIDE
ERTICAL
NSTALLATIONS
To accomplish an outside vertical pipe installation, follow the "H
section and then finish it by performing the following (refer to Figure 15).
1. Install a tee with clean out on the outside of the house.
2. Install PL vent upward from the tee. Make sure that you install support brackets to keep the vent
straight and secure. All joints in the exhaust venting system must be fastened with at least three (3)
screws.
3. Install ceiling thimble and secure the flashing as you go through the roof.
4. Ensure that the rain cap is a minimum of 24" (61 cm) above the roof.
Horizontal
Frame for
Thimble
16
Installation
:
Rain Cap
MIN 24"
(610mm)
3"MIN Clearance
(75mm)
All around
Wall Strap
3"(76mm) MIN.
Figure 15: Outside Vertical Installation.
E
T
ORIZONTAL
XHAUST
HROUGH
Storm Collar
Flashing
4' (1220mm) MAX
Clean Out Tee
Wall Thimble
Hampton GC60 Cast Pellet Stove Technical Manual