Page 1
Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference. 918-427a 10/25/11 FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4...
Page 2
Thank-you for purchasing a HAMPTON FIREPLACE PRODUCT. The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the HAMPTON DEALER in your area.
TABLE OF CONTENTS OPERATING INSTRUCTIONS SAFETY LABEL Operating Instructions ..........22 Safety Label..............4 Fan Operation..............22 First Fire ..............22 UNIT DIMENSIONS Safety Guidelines And Warnings .........23 Draft Control ..............23 Unit Dimensions with Standard Legs......5 Ash Disposal..............24 Unit Dimensions with Optional Short Legs ....6 Glass Maintenance ............25 INSTALLATION MAINTENANCE...
S2100 OR MODEL ASHT, SELKIRK MODEL SSII, OLIVER MACLEOD PRO JET 3103, SIMPSON DURA PLUS, GSW MODEL SC OR METAL-FAB TEMP/GUARD, AMERI-TECHS, ICC EXCEL 2100, SIMPSON DURA PLUS HTC . USE CHIMNEY COMPONENTS AS SPECIFIED IN INSTALLATION INSTRUCTIONS. MANUFACTURED BY: FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 VENTURE ST. DELTA, BC V4G 1H4...
INSTALLATION PRE-INSTALLATION Rotating Elbow 3) Slide the tabs on the rear heat shield in ASSEMBLY between the bolt and washer. This stove can be connected to either a top or rear vent exit by simply reversing the orientation Please Note: The shield needs to be stretched/ of the elbow.
INSTALLATION even reduced heat output. Too tall a chimney 9) When the fl oor protection is complete, posi- RESIDENTIAL may prompt excessive draft which can result tion the stove with the fl ue collar centered INSTALLATION in very short burn times and excessive heat under the installed chimney.
INSTALLATION MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS Please read the section below carefully. Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner, and from the rear heat shield to a back wall. Clearances may only be reduced by means approved by the regulatory authority.
INSTALLATION MINIMUM ALCOVE CLEARANCE TO COMBUSTIBLE MATERIALS This Hampton Freestanding model has been alcove approved and must be installed with a listed double wall connector to the ceiling level. Note: Minimum alcove ceiling height (from fi nished fl oor) - 60" (1525 mm) Maximum depth of alcove - 48"...
INSTALLATION FLOOR PROTECTION A combustible fl oor must be protected by non-combustible material (like tile, concrete board, or certifi ed to UL-1618 or as defi ned by local codes) extending beneath the heater and a minimum of 6" from each side and minimum 16" from the front face of the stove and minimum 6"...
INSTALLATION 7) For optimum effi ciency when installing into STEP-BY-STEP a masonry chimney, size accordingly, i.e. CHIMNEY AND the 6" (152mm) fl ue dia. is 28.28 sq.in. CONNECTOR 8) To complete your chimney installation, install the double wall connector pipe from the INSTALLATION stove’s fl...
INSTALLATION MASONRY CHIMNEY Ensure that a masonry chimney meets the minimum standards of the National Fire Protection Association (NFPA) by having it inspected by a professional. Make sure there are no cracks, loose mortar or other signs of deterioration and blockage. Have the chimney cleaned before the stove is installed and operated.
INSTALLATION RECOMMENDED HEIGHTS FOR WOODSTOVE FLUE Simple rules on draft. See Table 1. Example: a) Recommended Flue Height 1-1/2 ft. of horizontal run = 3 ft. Elevation Example a) Example b) one "T" = 3 ft. 1) At sea level minimum height is 12' Total Addition (at sea level) = 6 ft.
INSTALLATION INSTALLATION MOBILE HOME INSTALLATION Once you have properly marked the position In addition to standard installation instructions of your unit and the fl oor protection as outlined the following requirements are mandatory for in the Residential Installation items #1 through installation in a mobile home.
INSTALLATION INSTALLATION LISTED COMPONENTS FOR MOBILE HOME INSTALLATION The Hampton H200 Cast Freestanding unit is approved for installation in a Mobile Home if one of the following pipe systems is used. U.S. Installation* AMERI-TECHS Canadian Installations* Qty.Part # Description 6DCC Connector METALBESTOS SSII SECURITY S2100, SUPERVENT 2100...
INSTALLATION BRICK INSTALLATION OPTIONAL SHORT LEG DOOR REMOVAL INSTALLATION Firebrick is included to extend the life of your 1) Open door. stove and to radiate heat more evenly. Check to see that all fi rebricks are in their correct 2) Push spring lever down while holding onto 1) Remove the cast lid from the top of the positions and have not become misaligned the door.
INSTALLATION An optional blower is available for the Hampton OPTIONAL BLOWER/FAN INSTALLATION H200. The blower is factory assembled, wired and ready for attachment to the stove. 1) Remove fan cover plate from back shield 4) Hook fan over the bolts. by undoing 3 screws and discard plate.
INSTALLATION OPTIONAL SIDE SHELF INSTALLATION 1) Secure 2 Support Gussets to each Side Shelf using 2 screws per 4) Mount side shelf to stove and secure in place using the allen key gusset. provided to secure the 2 set screws. Ensure that the Bracket cut-out is towards Underside of Side Shelf Shown.
INSTALLATION OPTIONAL ASH DRAWER KIT INSTALLATION NOTE: This option is only available with use of standard legs. 1) Remove the andirons and bricks from within the fi rebox. 4) Re-install bottom tray and then install the 2 ash drawer rails to the bottom tray using 4 bolts.
OPERATING INSTRUCTIONS 3) With the draft still in the fully open position OPERATING add two or three seasoned logs to your fi re. 13) All fuel burning appliances consume oxygen INSTRUCTIONS Form a trench in the ash bed to allow air to during operation.
OPERATING INSTRUCTIONS INSTALLATION 13) Your woodstove should burn dry, standard SAFETY GUIDELINES DRAFT CONTROL fi rewood only. The use of cut lumber, ply- AND WARNINGS wood, “mill ends”, etc. is not allowed as this Both the primary and air wash drafts are control- fuel can easily overheat your woodstove.
OPERATING INSTRUCTIONS ASH DISPOSAL Optional Ash Drawer During constant use, ashes should be removed Operating Guideline every few days. The Ash Drawer features a convenient ash drawer for easy removal of 1) Only clean ashes out of the stove when the ashes.
MAINTENANCE GLASS MAINTENANCE Ways to Prevent and Keep Unit MAINTENANCE Free of Creosote Your Hampton stove is supplied with 5 mm It is very important to carefully maintain your Neoceram ceramic glass (Part #940-345) that stove, including burning seasoned wood and 1) Burn stove with the draft control wide open maintaining a clean stove and chimney system.
MAINTENANCE Front Door Handle Shown If position of bracketry needs to FRONT DOOR GASKET be changed after adjustment: If the front door gasket requires replacement The bracketry should start from the highest point, 5/8" diameter material must be used. Hampton as seen below.
MAINTENANCE 3) Remove the left and right baffl e caps by 5) Replace the Top Baffl e TOP BAFFLE removing the 2 bolts (7/16) socket 1/4-20 x REPLACEMENT 1/2" hex head on each side and lift out. 6) Reverse steps 4 to 1. 1) Lift the Top Hob off the top of the stove.
MAINTENANCE Annual Maintenance Completely clean out entire unit Annually Inspect air tubes, baffl es and bricks Replace any damaged parts. Adjust door catch / latch If unable to obtain a tight seal on the door - replace door gasket seal. Readjust latch after new gasket installed.
PARTS LIST H200 MAIN ASSEMBLY PART # DESCRIPTION PART# DESCRIPTION 1) 200-301 TOP CHARCOAL GREY 26) 820-376 RETAINER PLATE 200-305 TOP TIMBERLINE BROWN 27) 200-391 BASE CHARCOAL GREY 2) 200-522 FIREBOX TOP ASSEMBLY 200-395 BASE TIMBERLINE BROWN 28) 200-401 ASH LIP CHARCOAL GREY 3) 200-514 BAFFLE ASSEMBLY 200-405...
Page 30
PARTS LIST Hampton H200 Cast Freestanding Woodstove...
At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit. FPI has no obligation to enhance or modify any unit once manufactured. ie. as products evolve, fi eld modifi cations or upgrades will not be performed.