Service Access; Main Power - Jandy 200 Installation And Operation Manual

Pro series jxi gas-fired pool and spa heater
Table of Contents

Advertisement

Jandy
Pro Series, JXi
®
6.2

Service Access

The electrical component panel may be rotated up
and away from the heater body for easier access to the
electrical system. With the front panel removed, press the
tab in the raceway (as shown in Figure 20) , then rotate
the panel upward. The latch should hold in place.
1
Press Tab
To Release
2
Press to Release
and Return to Down Position
Lift Up
To Latch
Figure 20. Electrical System Service Access
6.3

Main Power

Electrical wiring must be in accordance with the latest
edition of the National Electric Code
National Fire Protection Association
in Canada, the Canadian Electrical Code (CSA
unless local code requirements indicate otherwise.
The heater comes factory-wired intended for use with 240
Volt, 60 Hz AC field electrical supply. To use 120 Volt,
60 Hz AC requires changing the position of the voltage
selector board on the power distribution board. This must
be done by a certified electrician only, as with all wiring.
Be sure that the power source to the heater is turned off or
disconnected before servicing.
NOTE
If the heater is converted to accept 120V, the "Hot"
wire of the 120V power supply has to be connected to
the black wire (ACH1) on the power distribution board
and the "Neutral" wire of the 120V power supply has
to be connected to the red wire (ACN1) of the power
distribution board.
To wire the heater to 120V or 240V/60 Hertz (Hz):
1.
Remove the front door panel of the heater.
2.
Connect the wires from the power source to the
leads on the heater (Figure 21).
NOTE
No external junction box is required.
|
Gas-Fired Pool & Spa Heater
(NEC
), ANSI
®
®
(NFPA
) 70, or
®
®
C22.1)
®
Installation & Operation Manual
WIRES AS SHIPPED
CONNECT WIRES INSIDE HEATER
Figure 21. Field Wiring Connections
6.3.1
Converting the Heater for a 120V Power
Source
/
®
ELECTRICAL SHOCK HAZARD. To avoid an
electrical shock hazard, which can result in serious
injury or death, ensure that all electrical power to the
system is turned off before approaching, inspecting, or
troubleshooting any leaking plumbing that may have
caused electrical devices in the surrounding area to
get wet.
The heater is configured at the factory to operate at 240
VAC, 60 Hz; to convert.the heater to 120 Volt, 60 Hz
AC, reverse the voltage selector board on the power
distribution board before the heater is connected to a
power source:
To convert the heater to 120V 60 Hertz (Hz):
1.
Identify the power distribution board on the heater
to the right of the ignition control on the raceway
(Figure 22).
Page 23
ENGLISH
WARNING
CONDUIT
ELBOW