Section 7. Operating Instructions; First-Time Start-Up Procedure; Starting The Heater - Jandy 200 Installation And Operation Manual

Pro series jxi gas-fired pool and spa heater
Table of Contents

Advertisement

Jandy
Pro Series, JXi
®
When the heater is connected to an external controller,
all functionality of the heater control panel is disabled,
therefore heater functions can be controlled only from the
controller.
To restore heater control panel functionality after
connecting to an external controller:
1.
Turn power to the heater ON. The heater display
shows: JANDY REMOTE ONLINE PUSH
MENU TO DISABLE .
2.
Press MENU to remove message and restore
functionality to the heater control panel.
To return functionality to RS:
1.
Turn power to the heater OFF then back ON.
2.
Press MENU for 5 seconds to access Setup Mode.
3.
Choose JANDY REMOTE.

Section 7. Operating Instructions

7.1

First-Time Start-Up Procedure

WARNING
Vent pipes and heater tops get hot! These surfaces
can cause serious burns. Do not touch these surfaces
while the heater is in operation.
Do not use this heater if any part has been under
water. Immediately call a qualified service technician to
inspect the heater and replace any part of
the control system and any gas control which has
been under water.
Should overheating occur or the gas supply fail to shut
off, turn off the manual gas control valve to the heater.
Do not attempt repairs on the gas controls or
appliance. Tampering is dangerous and voids all
warranties.
1.
Confirm that pool water is flowing normally
through the pool system and equipment.
2.
If it is a new pool or spa installation, operate the
filter pump with the heater off long enough to
completely clean the water. This will remove any
installation residue from the water.
3.
Clean the filter before starting the heater.
4.
Start the heater in either Pool or Spa mode (see
section 7.6, Operating the Heater).
5.
Start the heater (see section 7.2, Lighting the
Burner).
|
Gas-Fired Pool & Spa Heater
Installation & Operation Manual
6.
When the heater starts, confirm there is adequate
water flow by touching the outlet header. The
header should not be hot. Normally, water
temperature will rise only a few degrees as it
passes through the heater, and a "hot" header or
pipe indicates low water flow.
If ignition is unsuccessful:
If ignition is unsuccessful, or the flame fails during normal
operation, the ignition control shuts off the gas valve.
The heater will then go through a post purge process and
attempt to establish stable combustion two additional
times. If ignition is unsuccessful after three attempts,
the system shuts down and will automatically attempt to
restart after one hour.
To reset the heater to provide three (3) attempts to start:
1.
Turn OFF the control then turn it back ON.
2.
Access either the Pool or Spa mode.
7.2

Starting the Heater

Follow the instructions outlined below to start the heater.
Refer to the Lighting and Shutdown Instructions label on
the inside lid panel of the heater (Figure 29).
If you do not follow the instructions below exactly, a
fire or explosion may result, causing property damage,
personal injury or loss of life.
IMPORTANT SAFETY INFORMATION
Read Before You Start:
(A)
This appliance does not have a pilot light. It
is equipped with an ignition device, which
automatically lights the heater. Do NOT try to
light the burners by hand.
(B)
BEFORE OPERATING, smell all around the
appliance for gas. Be sure to smell next to the
floor because some gas is heavier than air and will
settle on the floor.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electric switch; do not use any
phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
- If you cannot reach your gas supplier, call the
Fire Department.