Water Pressure Switch Adjustment - Jandy 200 Installation And Operation Manual

Pro series jxi gas-fired pool and spa heater
Table of Contents

Advertisement

Jandy
Pro Series, JXi
®
Optionally, the top inlet opening may be capped with the
union nut and cap, and plug with O-ring provided, then
the water inlet port on the side directly above the outlet
port may be used. (See Figure 16.)
Figure 16. Optional Side Inlet Piping
WARNING
To avoid an electrical shock hazard, which can result
in serious injury or death, ensure that all electrical
power to the system is turned off before approach-
ing, inspecting or troubleshooting any leaking valves
or plumbing that may have caused other electrical
devices in the surrounding area to get wet.
WARNING
Follow all filter manufacturer's
instructions. NEVER attempt to
assemble, disassemble or adjust the
filter when there is pressurized air in
the system. Starting the pump while
there is any pressurized air in the
system can cause the filter lid to be
blown off, which can cause death,
serious personal injury or property
damage.
To install the Sweep Elbow:
1.
Clean the cut ends of the pipe and both ends of
the sweep elbow(s) with an appropriate NSF
approved All Purpose cleaner/primer. Glue the
sweep elbow(s) onto the cut pipe ends using an
appropriate All Purpose NSF approved adhesive/
glue.
NOTE
Zodiac Pool Systems, Inc. recommends Weld-On
724
PVC to CPVC Cement to glue Schedule 40
TM
PVC.
|
Gas-Fired Pool & Spa Heater
(union nut, cap
and O-ring provided)
IN
OUT
Installation & Operation Manual
2.
After the glue is cured, close the pressure relief
valve on top of the filter.
3.
Return all valves to their operating positions.
4.
Turn on power to the heater.
5.
Turn on the pump to check for water leaks.
6.
Restore the gas supply to the heater.
7.
Start the system and check for proper water flow.
5.4

Water Pressure Switch Adjustment

The water pressure switch should be adjusted to turn
the heater off when the pump is off. Setting the switch
to close at too low flow can damage the appliance.
Adjust the switch to turn the heater off, not on.
The pressure switch is preset at the factory for activation
at 2 psi (14 kPa). If the heater is installed below the
surface level of the pool, more than two feet above the
pool level, or any time the pressure is measured at 1 psi
or greater with the system pump off the pressure switch
setting must be adjusted.
Location of the heater above or below the pool water
surface can also affect the operation of the switch. The
factory installed switch can accommodate elevations not
exceeding 6 feet above the pool water surface or 11 feet
below pool water surface. If the heater water connections
are outside this range Consult your local Zodiac
representative for recommendations.
Make sure the pool filter is clean before making any
pressure switch adjustment. A dirty filter will restrict the
water flow and the pressure switch cannot be adjusted
properly.
To adjust the water pressure switch:
NOTE: It is recommended that a Pressure Release Valve
(PRV) be installed prior to taking any of the steps
below. See section 5.7
1.
Set the heater control to the "OFF" mode.
2.
Remove the header side panel to access the water
pressure switch.
®
3.
Start the filter pump and confirm by means of a
voltmeter that the pressure switch closes (if the
switch fails to close, replace it with a switch that
has a lower minimum setting).
Set the heater control to either POOL or SPA.
4.
Heater should start.
®
5.
With your fingers, turn the adjustment sprocket
very slowly clockwise until the heater goes off.
(See Figure 17.)
ENGLISH
CAUTION
Page 19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

260330400Pro jxi 330Jxi 200Jxi 260 ... Show all

Table of Contents