Chapter 3

Maintaining the Hardware

This chapter provides maintenance information for the PA-200 hardware. For more
information, refer to the following topics:
"Cautions and Warnings" in the next section
"Interpreting the Device LEDs" on page 12
"Interpreting the Port LEDs" on page 13

Cautions and Warnings

This section describes the cautions and warnings that you must be familiar with before
working with the hardware:
"Hardware Cautions" on page 11
"Hardware Warnings" on page 11
Hardware Cautions
Disconnect the power cord before servicing the PA-200 firewall.
Shielded Ethernet interface cables should be used to ensure agency compliance with
electromagnetic emissions (EMC). Connecting a PoE enabled port to the firewall is not
recommended because the system does not support the PoE operating mode.
To prevent damage from electrical surges, use a Uninterruptible Power Supply (UPS) and
implement the facilities lightning protection requirements outlined in the National Fire
Protection Association (NFPA) 780: Standard for the Installation of Lightning Protection
Systems (or similar effective measures per local regulations).
Hardware Warnings
Risk of explosion if the battery is replaced with an incorrect type. Dispose of used
batteries in accordance with government regulations.
Palo Alto Networks
Maintaining the Hardware • 11