Resetting the Lamp Life Counter
The lamp lasts a maximum of 1,500 hours. The projector is
designed to shut off power if the lamp is used beyond this
1,500 hours. In such case, replace the lamp and reset the lamp
life counter as follows.
1.
After the "Lamp Life 0 Hours" message appears on the
screen, power to the projector shuts off. Promptly replace
the lamp with a new one. (See "Lamp Unit Replacement"
pg. 36.)
2.
After replacing the lamp, press either the POWER button
on the projector or the POWER ON button on the remote
controller.
The below message will appear on the screen for about
120 seconds.
New Lamp ?
Yes
3.
Select "Yes" using the
4.
Press the ENTER button to reset the lamp life counter.
4
ENTER
STANDBY
36
Downloaded From projector-manual.com Marantz Manuals
No
1
2
and
buttons.
STANDBY
PATTERN
INPUT
MENU
POWER
3
POWER ON
2.
PATTERN
PATT.
MENU
V-MUTE
4.
ENTER
3.

Lamp Unit Replacement

Note:
• The lamp is very hot while lit and shortly after being turned
off. Do not touch the lamp or lamp unit while hot. Wait at
least 1 hour for the lamp to cool down before handling it.
• Do not loosen any screws except those specifically
mentioned in the below procedure.
• The lamp may break under excessive force or mechanical
shock.
• Use only the Marantz original lamp unit LU10VPS1 (sold
separately).
How to Replace the Lamp
Preparation:
Turn off power to the projector before replacing the lamp.
After the cooling fan stops, unplug the AC power cable
and wait at least 1 hour for the lamp to cool down. Then,
replace it.
1.
Press the STANDBY button on the remote controller or
the POWER button on the projector to shut off power to
the projector.
ON
2.
After the cooling fan stops, set the ON/OFF switch in the
2
OFF position and unplug the AC power cable.
3.
Wait at least 1 hour for the projector to cool down
sufficiently.
4.
Locate the lamp cover on the projector rear (see below).
Read the caution and warning labels on the cover.
Lamp cover
VIDEO IN S-VIDEO IN COMPONENT VIDEO IN 1
COMPONENT VIDEO IN 2
Y
P
/C
P
/C
Y
P
/C
P
/C
B
B
R
R
B
B
R
R
REMOTE
TRIG.
LIGHT
RGB IN
DVI-D IN
RS-232C
IN
1
INT.
EXT.
OFF ON
CAUTION
CAUTION HOT
2
HIGH-PRESSURE LAMP MAY EXPLODE IF IMPROPERLY
UNPLUG THE POWER CORD AND WAIT 60
OUT
HANDLED. REFER SERVICING TO QUALIFIED SERVICE
MINUTES BEFORE CHANGING THE LAMP.
PERSONNEL.
ATTENTION
ATTENTION CHAUD
LA LAMPE SOUS HAUTE PRESSION PEUT EXPLOSER
DEBRANCER LE CORD ON D'ALIMENTION ET
SI ELLE, N'EST PAS MANIPULEE CORRECTEMENT,
ATENDER 60 MINUTES AVANT DE CHANGER
CONFIER L'OPERATION A UN PERSONNEL D'ENTRETIEN
QUALIFIE.
LAMPE.
VORSICHT
WARNUNG HEISS
BEI FALSCHER HANDHABUNG KANN DIE
ZIEHEN SIE DEN NETZSTECKER AB UND
HOCHDRUCKLAMPE EXPLODIEREN UBERLASSEN SIE
WARTEN SIE 60 MINUTEN BEVOR SIE DIE
WARTUNGSARBEITEN NUR FACHPERSONAL.
GLUHLAMPE WECHSELN.
CAUTION
CAUTION HOT
HIGH-PRESSURE LAMP MAY EXPLODE IF IMPROPERLY
UNPLUG THE POWER CORD AND WAIT 60
HANDLED. REFER SERVICING TO QUALIFIED SERVICE
MINUTES BEFORE CHANGING THE LAMP.
PERSONNEL.
ATTENTION
ATTENTION CHAUD
LA LAMPE SOUS HAUTE PRESSION PEUT EXPLOSER
DEBRANCER LE CORD ON D'ALIMENTION ET
SI ELLE, N'EST PAS MANIPULEE CORRECTEMENT,
ATENDER 60 MINUTES AVANT DE CHANGER
CONFIER L'OPERATION A UN PERSONNEL D'ENTRETIEN
LAMPE.
QUALIFIE.
VORSICHT
WARNUNG HEISS
BEI FALSCHER HANDHABUNG KANN DIE
ZIEHEN SIE DEN NETZSTECKER AB UND
HOCHDRUCKLAMPE EXPLODIEREN UBERLASSEN SIE
WARTEN SIE 60 MINUTEN BEVOR SIE DIE
WARTUNGSARBEITEN NUR FACHPERSONAL.
GLUHLAMPE WECHSELN.
STANDBY
POWER ON
PATTERN
PATT.
MENU
V-MUTE
ENTER

Advertisement

Table of Contents
loading

Table of Contents