Description Of Fault Codes - Jenn-Air JGS8750ADB Service Manual

Gas slide-in range
Hide thumbs Also See for JGS8750ADB:
Table of Contents

Advertisement

Testing Procedures
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing,
unless testing requires power and/or gas.

Description of Fault Codes

Each Fault Code consists of an "F" followed by a number, dash and a number or letter. The following table
describes each Fault Code and the component to troubleshoot.
To view the most recent fault code:
1. Press and hold the Cancel and Broil pads for 3 seconds at power-up, or within 5 minutes of power-up.
2. Once the control has entered the "Quick Test" mode, release both pads.
3. Press the Cook Time pad to view the most recent fault (displayed in the control display window).
Fault
Code
F0-0
No Fault.
Oven temperature above 650° F (343° C) in bake mode.
F1-1
Oven temperature above 950° F (510° C) during a clean
F1-3
cycle.
F1-5
Cancel pad not responding.
F1-7
Membrane disconnected.
F1-8
Shorted key (pad) in membrane switch.
F1-9
Internal control communication errors.
F1-A
Lock/unlock switch state not advancing to control.
F1-C
Oven door switch state not advancing to control.
F1-E
Control not calibrated.
F1-F
Jumper not removed from printed circuit board (PCB).
F1-H
EEPROM error.
F1-N
Internal voltage for slave micro incorrect.
F3-1
Open or shorted sensor.
F8
Shorted meat probe.
F9-1
Oven door will not lock.
F9-2
Oven door will not unlock.
F9-3
Oven door status is both locked and unlocked.
©2005 Maytag Services
!
WARNING
Description
16022089
Component to Troubleshoot/Replace
None.
Ohm sensor and harness (see "Oven Sensor" chart, pg
12). If OK, change control.
Ohm sensor and harness (see "Oven Sensor" chart, pg
12). If OK, change control.
Ensure ribbon cable is securely connected, inspect
ribbon cable and connector (shorts, breakage, corrosion,
etc.). If OK, replace control.
Ensure ribbon cable is securely connected, inspect
ribbon cable and connector (shorts, breakage, corrosion,
etc.). If OK, replace control.
Ensure ribbon cable is securely connected, inspect
ribbon cable and connector (shorts, breakage, corrosion,
etc.). If OK, replace control.
Replace control.
Check connections, harness, and motor. If OK, replace
control.
Check connections, harness, and motor. If OK, replace
control.
Replace control.
Remove jumper from PCB.
Replace control.
Replace control.
Ohm sensor and harness.
Check probe jack and harness probe jack harness. If
OK, check meat probe (see "Meat Probe" chart, pg 12).
Check wire connections. If OK, replace motorized door
lock.
Check wire connections. If OK, replace motorized door
lock.
Check wire connections. If OK, replace motorized door
lock.
21