Download Print this page

Installation Instructions; Regulations And Provisions; Important Note; Installation Location - STIEBEL ELTRON DJ 30 E Operation And Installation Instructions Manual

Instantaneous shower water heater

Advertisement

2. Installation instructions

for the user and the qualitifi ed installer
2.1 Technical data
1. Thermostat
2. Position for electrical connection
3. Cable duct for electrical connection
4. Power light
5. Rotary control for temperature
adjustment
6. Cold water connection
7. Hot water connection for shower
hose
8. Lower fixing hole
9. Uper fixing hole
10. ELSD (option)
11. Connection cable
12. Cover securing screw
13. Depth for mounting screw
14. Rear wall installation
15. Combination filter/seal
16. Washer
17. Union nut and washer, provide
by client
18. Water valve

2.2 Regulations and Provisions

- Regulations of the local power supply
anthority should be observed.
- Regulations of the water supply
anthority should observed
- Technical data.
- Install the unit flush with the wall.
- Electrical connection to be secure.
The device must be capable of
being isolated from the mains, for
example by fuses, with an isolating distance
of at least 3,5 mm, in all poles.
The unit must be earthed (see circuit
diagram). To protect against water
penetration, the cable seal (3) must be used.

2.3 Important note

All the information in these operating
and Installation Instructions must
be carefully followed. These instructions
provide important details regarding the
safety, operation, installation, and maintenance
of the unit.

2.4 Installation location

The shower unit is to be installed
in a closed, frost-free room (disconnected
units are to be stored in a frost-free location,
since there will always be some water left in
the unit) The DJ is to be installed vertically on
a wall (hot water connection downwards).
2.5 Installing the unit
1. Flush the cold water pipe thoroughly.
2. Fit a secure connection cable (11
ensure dimensions are correct).
3. Release cover securing screw (12).
4. Remove cover.
5. Determine the position of the drill
holes and drill the holes. Insert the
wall plugs and screw in the screws
(ensure screw insertion depth is
correct, 13).
6. Feed the connection cable through
the cable seal (3) in the rear wall.
Guide the unit over the wall securing
screws.
7. Fit the cold water connection.
Connect the water valve (18) with
the filter (15) and the washer (16)
to the cold water inlet of the unit
(6). Tighten the union nut and
washer (17) to the water valve.
8. Straighten the unit and tighten the
screws.
9. Connect the electrical supply.
10. Fit the cover and secure with the
screw.
11. Turn the rotary control (B) to the
left and right (internal setting lever
will engage).
12. Fit the shower accessories to the
unit.
The outlet must not be connected
to any tap or fitting other than those
specified. 2.6 First operation (Only to be
carried out by a qualified installer)
Before switching on, set the rotary
water valve to "Max" setting until
the pipework and the unit are free of air.
- Before switching "ON", set the rotary
temperature control to "OFF"
- Check the operation of the water heater.
Handing over the unit
Explain to the user how the unit works and
familiarise him or her with its use.
- Advise the user about possible hazards
(high water temperature)
- Hand over these instructions, to be kept
in a safe place.
Do not switch on if there is a possibility
that the water in the heater is frozen.
(This warning is not required if the appliance
Incorporates a flow switch.
2.7 Service note
When carrying out any work,
isolate the unit from the mains
and shut off the water connection.
- Clean the filter
Disconnect water valve (18), remove
filter (15) and clean . Re-assemble
in reverse order.
5

Advertisement

loading