1. Installation instructions
for the user and the qualitifi ed installer

1.1 Description of the unit

The STIEBEL ELTRON DJ pressureless (open)
small instantaneous is device for heating
water for shower. The electrical power is
electronically controlled. The flow is
switched on and off by using the water
valve. The unit switches the power on
once the flow volume is sufficient.
The "Power" light indicates the unit is
switched on. The unit is fitted with an
overheating protection device.
The DJ is also equipped with an aerojet
system that blends water with air for that
fizzling feeling on your shower.
1.2 The essentials - in brief
A Water valve
B Rotary control for temperature
adjustment
C "Power" light
D Shower accessories
1.3 Important information
The unit must not be put under
pressure. The outlet of the unit
is also used as a vent. A periodical scale
removal is essential for the function of the
shower head.

1.6 Technical data

(the data on the unit rating plate apply)
Type
Design
Rated pressure
Cold water connection
Electrical connection
Dimension
(W x H x D)
Rated power (kW) - Rated current (A)
Recommended circuit breaker
Recommended cable size
(Sqmm.)
The unit is optionally equipped
with an ELSD (Type DJ..E only)
It is recommended to test the ELSD one
time per month.
How to test:
Switch on the electrical supply. Press the
Test button, the Trip light will go on. Press
the Reset button.
Warning!
If the Trip light activate after reset
or if the light activate during shower, never
try to fix it. Contact your dealer for a check
and repair.
Warning!
If, during a shower , the water
valve is closed, (such as applying soap to
the body), then valve opened again, high
water temperature may occur, to avoid risk
of scalding, stay any from the shower head
discharge zone momentarilly.
1.4 Care and Maintenance
All that is needed for the housing is a damp
cloth. Do not use any abrasive cleaning
agents or agents containing solvents.
(mm.)
220 V
230 V
240 V
(A)
Maintenance work may only be
carried out by a qualified installer.
1.5 Hot water capacity
The hot water capacity depends on the
power of the unit, the cold water temperature,
and the flow volume.
Thermostat cut-off is a service
case only for qualified technician
- This appliance is not intended
for use by persons (including
children) with reduced physical, sensory or
mental capabilities, or lack of experience
and knowledge, unless they have been
given supervision or instruction concerning
use of the appliance by a person responsible
for their safety.
- Children should be supervised to
ensure that they do not play with
the appliance.
DJ
30 E
Open outlet
0MPa / 0 bar
G 1/2"
1/N/PE ~ 220 .... 240 V
200 x 360 x 104
kW - A
3.0 - 13.6
3.3 - 14.3
3.6 - 15.0
15
2.5