STIEBEL ELTRON DHF 13 C Operating And Installation

Hydraulically controlled instantaneous water heater

Advertisement

BEDIENUNG UND INSTALLATION
OPERATING AND INSTALLATION
UTILISATION ET INSTALLATION
GEBRUIK EN INSTALLATIE
OPERACIÓN E INSTALACIÓN
OBSLUHA A INSTALACE
OBSŁUGA I INSTALACJA
ОБСЛУЖВАНЕ И ИНСТАЛИРАНЕ
ЭКСПЛУАТАЦИЯ И МОНТАЖ
‫االستعمال والتركيب‬
Hydraulisch gesteuerter Durchlauferhitzer | Hydraulically controlled instantaneous
water heater | Chauffe-eau instantané à commande hydraulique | Hydraulisch
gestuurde doorstromer | Calentador instantáneo controlado hidráulicamente |
Hydraulicky řízené průtokové ohřívače | Hydraulicznie sterowany przepływowy
ogrzewacz wody | Хидра влично контролиран проточен бойлер | Проточный водонагреватель
с гидравлическим управлением |
‫سخان المياه الفوري ذو التجكم الهيدروليكي‬
» DHF 13 C
» DHF 15 C
» DHF 18 C
» DHF 21 C
» DHF 24 C
» DHF 12 C1
» DHF 13 C3

Advertisement

Table of Contents
loading

Summary of Contents for STIEBEL ELTRON DHF 13 C

  • Page 1 Hydraulicky řízené průtokové ohřívače | Hydraulicznie sterowany przepływowy ogrzewacz wody | Хидра влично контролиран проточен бойлер | Проточный водонагреватель с гидравлическим управлением | ‫سخان المياه الفوري ذو التجكم الهيدروليكي‬ » DHF 13 C » DHF 15 C » DHF 18 C » DHF 21 C »...
  • Page 2: Table Of Contents

    CONTENTS | SPECIAL INFORMATION SPECIAL INFORMATION SPECIAL INFORMATION OPERATION General information ��������������������������������������� 19 - The appliance may be used by children aged 3 Safety instructions ���������������������������������������������� 19 and up and persons with reduced physical, sen- Other symbols in this documentation ���������������������� 19 sory or mental capabilities or a lack of experience Units of measurement �����������������������������������������...
  • Page 3: General Information

    OPERATION General information OPERATION Other symbols in this documentation Note General information is identified by the symbol shown on the left. General information f Read these texts carefully. The chapters "Special Information" and "Operation" are intended for both the user and qualified contractors. Symbol Meaning The chapter "Installation"...
  • Page 4: Safety

    OPERATION Safety Safety Settings Intended use This appliance is intended for domestic use. It can be used safely by untrained persons. The appliance can also be used in a non-do- mestic environment, e.g. in a small business, as long as it is used in the same way.
  • Page 5: Cleaning, Care And Maintenance

    OPERATION Cleaning, care and maintenance Following an interruption of the water supply Material losses Following an interruption of the water supply, the appliance must be recommissioned by carrying out the following steps: f Disconnect the appliance from the power supply by removing the fuses/tripping the MCBs.
  • Page 6: Installation

    INSTALLATION Safety INSTALLATION - Compression fitting - copper pipe - Compression fitting - plastic pipe (suitable for Viega: San- fix-Plus or Sanfix-Fosta) Universal mounting frame Safety Mounting frame with electrical connections. Only a qualified contractor should carry out installation, commis- sioning, maintenance and repair of the appliance.
  • Page 7: Installation

    INSTALLATION Installation Taps/valves Oversink installation Use appropriate pressure taps. Open taps are not permitted. Thermostatic pressure valves must be suitable for hydraulically controlled instantaneous water heaters. Note Never use the shut-off valve in the cold water inlet to reduce the flow rate. It is intended for shutting off the appliance.
  • Page 8 INSTALLATION Installation Fitting wall mounting bracket and appliance f Seal and insert the twin connectors. 1 Wall mounting bracket 2 Threaded stud 3 Threaded bush f Remove the wall mounting bracket. f Mark out the drill holes with the installation template (in the 1 Cold water with 3-way ball shut-off valve centre section of these instructions).
  • Page 9: Installation Options

    INSTALLATION Installation 10.2 Installation options Fitting the cable grommet 10.2.1 Power cable for finished walls Material losses If you break open the wrong knock-out in the appliance cover by mistake, you must use a new appliance cover. f Cleanly cut or break out the required opening in the appli- ance cover (see chapter "Installation / Specification / Dimen- sions and connections").
  • Page 10: Completing The Installation

    INSTALLATION Commissioning f Fit the appliance cover. Check that the appliance cover is Material losses seated correctly. If you cut open the wrong knock-out in the appliance f Secure the appliance cover with a screw. cover by mistake, you must use a new appliance cover. f Insert the cap.
  • Page 11: Troubleshooting

    INSTALLATION Troubleshooting 13. Troubleshooting Fault Cause Remedy No hot water. The fuse/MCB in the fuse box has blown/responded. Check the fuse/MCB in your fuse box/distribution panel. The heating system is faulty. Replace the tubular heater heating system. The appliance does not start. The mains water pressure is too low.
  • Page 12: Specification

    INSTALLATION Specification 15. Specification 15.2 Wiring diagram 3/PE ~ 400 V DHF 13 C, DHF 15 C, DHF 18 C, DHF 21 C, DHF 24 C 15.1 Dimensions and connections 3/PE ~ 230 V DHF 13 C3 ≤12 3’ 1’ 2’ I > b02 Entry electrical cables I 1/N/PE ~ 220-230 V DHF 12 C1 Cold water Inlet...
  • Page 13: Dhw Output

    GUARANTEE | ENVIRONMENT AND RECYCLING 15.3 DHW output The DHW output is subject to the mains voltage, the appliance's connected load and the cold water inlet temperature. The rated voltage and rated output can be found on the type plate (see chapter "Installation / Troubleshooting").
  • Page 14: Details On Energy Consumption

    Product data complies with EU regulations relating to the Directive on the ecodesign of energy related products (ErP). DHF 13 C DHF 15 C DHF 18 C DHF 21 C DHF 24 C DHF 12 C1 DHF 13 C3 074301...
  • Page 15 GUARANTEE | ENVIRONMENT AND RECYCLING Guarantee The guarantee conditions of our German companies do not apply to appliances acquired outside of Germany. In countries where our subsidiaries sell our products a guarantee can only be issued by those subsidiaries. Such guarantee is only grant- ed if the subsidiary has issued its own terms of guarantee.
  • Page 16   Deutschland Verkauf Tel. 05531 702-110 | Fax 05531 702-95108 | info-center@stiebel-eltron.de STIEBEL ELTRON GmbH & Co. KG Kundendienst Tel. 05531 702-111 | Fax 05531 702-95890 | kundendienst@stiebel-eltron.de Dr.-Stiebel-Straße 33 | 37603 Holzminden Ersatzteilverkauf Tel. 05531 702-120 | Fax 05531 702-95335 | ersatzteile@stiebel-eltron.de Tel.