Protocol Nmea $Zczda - WEMPE 20097 Operating Instructions Manual

Digital main clock
Hide thumbs Also See for 20097:
Table of Contents

Advertisement

1.1.4 Protocol NMEA $ZCZDA

Data scope:
1 Start bit
7 Data bit
1 Parity bit (even)
2 Stop bit
4.800 Baud
transmission once a second
Byte Mark
1 $
2 Z
3 C
4 Z
5 D
6 A
7 ,
8 10h
9 1h
10 10m
11 1m
12 10s
13 1s
14 .
15 1/10s
16 1/100s
17 ,
18 10d
19 1d
20 ,
21 10m
22 1m
23 ,
24 1000y
25 100y
26 10y
27 1y
28 ,
29 Dif. 10h
30 Dif. 1h
31 ,
32 Dif. 10m
33 Dif. 1m
34 *
35 CS Z
36 CS E
37 CR
38 LF
V3.0 01/2011
Description
HEX24
HEX5A
HEX43
HEX5A
HEX44
HEX41
HEX2C
Hour ten
Hour one
Minute ten
Minute one
Second ten
Second one
HEX2E
Second tenth
Second hundredth
HEX2C
Day ten
Day one
HEX2C
Month ten
Month one
HEX2C
Year thousand
Year hundred
Year ten
Year one
HEX2C
Difference hour ten
Difference hour one
HEX2C
Difference minute ten
Difference minute one
HEX2A
numeral or 30..39
letter or 41..46
HEX0D
Carriage return
HEX0A
Line feed
WEMPE digital main clock 20097
Annex
51

Hide quick links:

Advertisement

Table of Contents
loading