1.1.7 Protocol GORGI

Data scope:
1 Start bit
7 Data bit
1 Parity bit (even)
2 Stop bit
4.800 Baud
transmission once a second
Byte Mark
1 STX
2 weekday
3 weekday
4 weekday
5 SPACE
6 10d
7 1d
8 /
9 10m
10 1m
11 /
12 10y
13 1y
14 SPACE
15 SPACE
16 10h
17 1h
18 :
19 10m
20 1m
21 :
22 10s
23 1s
24 CR
25 NUL
54
Description
HEX02
Start of text
HEX20
Day ten
Day one
HEX2F
Month ten
Month one
HEX2F
Year ten
Year one
HEX20
HEX20
Hour ten
Hour one
HEX3A
Minute ten
Minute one
HEX3A
Second ten
Second one
HEX0D
Carriage return
HEX00