Annex

1.1.5 Protocol ECHO

Data scope:
1 Start bit
7 Data bit
1 Parity bit (even)
2 Stop bit
4.800 Baud
transmission once a second
Byte Mark
1 LF
2 LF
3 NUL
4 NUL
5 NUL
6 NUL
7 NUL
8 NUL
9 NUL
10 NUL
11 NUL
12 NUL
13 G
14 10h
15 1h
16 10m
17 1m
18 10s
19 1s
20 L
21 10h
22 1h
23 10m
24 1m
25 10s
26 1s
27 D
28 10d
29 1d
30 10m
31 1m
32 10y
33 1y
34 CR
52
Description
HEX0A
Line feed
HEX0A
Line feed
HEX47
Data transmission of the UTC-time
Hour ten
Hour one
Minute ten
Minute one
Second ten
Second one
HEX4C
Data transmission of the LT-time
Hour ten
Hour one
Minute ten
Minute one
Second ten
Second one
HEX44
Data transmission of the UTC-date
Day ten
Day one
Month ten
Month one
Year ten
Year one
HEX0D
Carriage return
V3.0 01/2011