Izolační Odpor Kamen; Resetování Ochrany Proti Přehřátí - Harvia CS60 Instructions For Installation And Use Manual

Electric sauna heater
Hide thumbs Also See for CS60:
Table of Contents

Advertisement

EN
of PVC-insulated wire as the connecting cable
of the heater is forbidden.
If the connecting and installation cables
are
higher than 1000 mm from the floor in the
sauna or inside the sauna room walls, they
must be able to endure a minimum temperature
of 170 °C when loaded (for example, SSJ).
Electrical equipment installed higher than
1000 mm from the sauna floor must be
approved for use in a temperature of 125 °C
(marking T125).
In addition to supply connectors, the CS heaters
are equipped with a connector (P), which makes
the control of the electric heating possible
(figure 10). Voltage control is transmitted from
the heater when it is switched on. The control
cable for electrical heating is brought directly
into the junction box of the heater, and from
there to the terminal block of the heater along
a rubber cable with the same cross-section
area as that of the connecting cable.
3.3.1. Electric Heater Insulation Resistance
When performing the final inspection of the electri-
cal installations, a "leakage" may be detected when
measuring the heater's insulation resistance. The
reason for this is that the insulating material of the
heating elements has absorbed moisture from the
air (storage, transport). After operating the heater
for a few times, the moisture will be removed from
the heating elements.
Do not connect the power feed for the heater
through the RCD (residual current device)!
3.4. Resetting the Overheat Protector
If the temperature of the sauna room becomes dan-
gerously high, the overheat protector will perma-
nently cut off the supply of the heater. The overheat
protector can be reset after the heater has cooled
down.
See figure 9. Prior to pressing the button, the cause
of the fault must be found.
Are the
stones crumbled and
together?
Has the heater been on for a long time
while unused?
Is the sensor of the thermostat out of place or
broken?
Has
the
heater been banged or
shaken?
Obrázek 9.
Resetování ochrany proti přehřátí
CZ
3.3.1. Izolační odpor kamen
Při měření izolačního odporu před sepnutím kamen
se může jevit jako špatný, tento odpor je způsoben vlhkostí
kolem spiral kamen a po sepnutí by se měl odpor dostat do
normálu.
3.4. Resetování ochrany proti přehřátí
Když je teplota v sauně nebezpečně vysoká,
Ochrana proti přehřátí vypne Kamna,
Kamna nebudou znovu topit dokud se nezmáčkne
Reset ochrany proti přehřátí.
pressed
Obr. 9.
Před resetováním zkontrolujte jestli nejsou spiraly
blízko u sebe.
Jestli Kamna dlouho před tím nejely.
Je čidlo termostatu rozbité nebo umístěno jinak.
Netřáslo se s kamny?

Advertisement