Adjustment; Hv Regulation Adjustment; B Max Voltage Confirmation - Sony KP-FX532M90 Service Manual

Table of Contents

Advertisement

KP-FX432M90/FX532M90
RM-1014

4-1. HV REGULATION ADJUSTMENT

(D Board)
When replacing the following components marked with ]
on the schematic diagram, always check hold-down volt-
age and if necessary re-adjust.
[ : RV8002
] : R8014, R8015, R8017
IC8005
PH8003
T8001(RHT)
HV block, D board
1. Connect a HV static voltmeter to the unconnected plug
of the highvoltage block. (Fig.4-1)
2. Videio input with all white signal.
Set "FULL" mode & "Personal".
Set the PICTURE (max.) and BRIGHTNESS (min.) set-
tings.
3. Power on the set.
4. Confirm that the static voltmeter reading is
31.0 ± 0.2 kV.
5. If not, adjust with RV8002 to the specified value.
6. After adjustment, apply sufficient amound of RTV
KE490 on the RV8002. (Fig.4- 2)
NOTE : This adjustment within 1 minute-3 minutes
after powrering.

4-2. +B MAX VOLTAGE CONFIRMATION

The following adjustments should always be performed
when replacing IC6801, R6809
1. Supply 220V AC to variable autotransformer.
2. Receive dot signal pattern and set the PICTURE and
BRIGHTNESS setting to their minimum.
3. Confirm the voltage of TP+B 135V is less than 137.0
Vdc.
4. If step 3 not satisfied, replace IC6801 and repeat above
steps.
SECTION 4

ADJUSTMENT

4-3. +B OVP CONFIRMATION
1. Supply 220V AC to variable autotransformer.
2. Turn on set.
3. Receive dot signal pattern.
4. Set the PICTURE (minimum) and BRIGHTNESS
(minimum) settings.
5. Turn off set.
6. Separate R6809 (D Board) from +135V.
7. apply external 160V ± 1VDC to open end of R6809.
8. Turn on set.
9. Confirm the LED blin ks 3 items.
10. Turn off the SET.
Then nount the R6809 corrlctly.
Fig. 4-1
– 74 –
Remove the cap off
from the unused
terminal and connect a
HV static voltmeter
there.
RV8002
Fig. 4-2
RTV KE490