PVVK-24H AND PVVK-48H CO-AXIAL VENT KIT

Step 1.
Install foam gasket on back side of co-axial direct vent
adaptor.
Step 2.
Attach co-axial direct vent adaptor and gasket (4 screws)
to the rear of fireplace.
Step 3.
Attach co-axial air-inlet duct to rear of fireplace (6
screws).
30259-6-0314
Available from Empire Comfort Systems, Inc.
Step 4.
Step 5.
Step 6.
Install silicone around connection between co-axial
adaptor and co-axial air-inlet duct.
Slide co-axial vent pipes into co-axial adaptor.
Cut the PVC co-axial pipes at this time.
Minimum horizontal vent length 4 1/2" (11.4 cm)
Minimum tube length 3 13/16" (9.7 cm)
Direct vent co-axial venting is completed.